Use
this macro to enable the audit and version utility and to define the
group and the type of members in that group to record audit and version
information for.
You must specify the name of the VSAM data
sets to contain the audit information and the name of the partitioned
data sets to contain the versions using the FLMCNTRL and FLMALTC macros.
You can define multiple versioning partitioned data sets for a project.
Using
the group and type defined in the FLMATVER macro, SCLM records information
in the VSAM data set each time a member's accounting information is
created, updated, or deleted within that SCLM group. This information
is a record that contains the member's accounting information, the
type of operation, the user ID of the user who performed the operation,
and the date and time the operation occurred.
You can use the
FLMATVER macro to store a version of a member. The member is stored
when the particular SCLM operation (such as SAVE) has completed successfully.
The version contains the information to recreate the member as it
previously existed. You can disable the versioning function while
maintaining the audit capabilities. Version information is captured
each time an editable member or an output that is not record format
U is created or updated, but not when it is deleted. Sequence
number differences can be ignored by coding the SEQNUM parameter,
otherwise, they are treated as data.
Macro format
>>-FLMATVER--GROUP=-+-group-+--,TYPE=-+-type-+------------------>
'-*-----' '-*----'
>--+-----------------------+--+-------------------+------------->
'-,SEQNUM=-+-STANDARD-+-' | .-NO--. |
+-STD------+ '-,VERSION=-+-YES-+-'
+-COBOL----+
'-NONE-----'
>--+----------------------------+--+--------------------+------><
'-,VERCOUNT=number_to_retain-' | .-YES-. |
'-,CHECKSUM=-+-NO--+-'
Parameters - GROUP|*
- The name of the group for which the audit data, version data,
or both, is to be maintained. The group must be defined in the project.
Use an asterisk (*) to indicate all groups.
- ,TYPE|*
- The name of the type for which the audit data, version data, or
both, is to be maintained. The type must be defined in the project.
Use an asterisk (*) to indicate all types.
Audit information can
be captured for editable or noneditable types. Version information
can be captured for editable types and non-editable types that are
not record format U. This means that you can maintain version information
for types such as "source" and "object", but not for load modules
or other data that has record format U. Therefore, if you have a project
with record format U data, such as load modules, do not specify
TYPE=* and VERSION=YES. If you attempt to version data that is record
format U, an error message is issued during SCLM processing.
- ,SEQNUM=STANDARD|STD|COBOL|NONE
- If you specify STANDARD, STD, or COBOL, SCLM ignores sequence
number differences when creating a version of a member.
STANDARD
or STD means ignore differences in the last eight columns of the data
for fixed formats, and the first eight columns of the data for variable
formats. In both cases the ignored columns are presumed to be standard
sequence numbers.
COBOL means ignore differences in the first
six columns of the data, which are presumed to be COBOL sequence numbers.
Omitting
this parameter, or specifying NONE, indicates that all columns are
to be treated as data. Note: When changing the value of the SEQNUM
specification for a project, also change the VERPDS specification
on the FLMCNTRL or FLMALTC macros for the affected groups. Failure
to do so may cause checksum verification errors when attempting to
recover versions created with the previous specification (see the
CHECKSUM keyword).
- ,VERSION=YES|NO
- If you specify YES, both the versioning and auditing processes
are active. If you specify NO, versioning is not active; however,
the audit process is active. If not specified, VERSION will default
to NO. Version data can be captured for any editable or non-editable
(output) members that are not record format U.
Note: You cannot
have versioning without auditing.
- ,VERCOUNT=number_to_retain
- The number of versions to keep in the version partitioned data
set for the group or type specified. If you specify a value of zero
(0), then all versions associated with a member are kept.
If you
specify a value of two (2) or more, each time a member is changed
the latest copy of the member is stored and the earliest copy is deleted,
so that the number of versions remains constant. Any audit records
that are associated with versions that have been deleted are retained,
but no longer indicate that a version of the member exists. If you
do specify a value of two or more, allocate a separate VERPDS for
each combination of group and type that has versioning enabled.
Note: Failure
to allocate a separate VERPDS for each combination of group and type
can cause retrieval problems. Use the FLMALTC macro, or use the @@FLMGRP
variable in the VERPDS name.
If a VERCOUNT value is not
specified on the FLMATVER macro or if a value of one (1) is specified,
then the value specified using the VERCOUNT parameter on the FLMCNTRL
macro is used. If a VERCOUNT value is not specified on either macro,
then all versions associated with a member are kept.
- ,CHECKSUM=YES|NO
- If you specify YES or omit this parameter, checksum verification
of versions on retrieval is in effect.
In the case of message
FLM39220 Return Code 34, which indicates a damaged version or a version
created before SEQNUM support was available in SCLM, you may take
this action to override the checksum verification failure:
- Insert the CHECKSUM=NO parameter.
- Reassemble the project definition.
- Retry retrieval of the version.
Attention: The validity
of the retrieved version is not assured. This procedure is recommended
for emergency use only.
Example The statements shown here illustrate
how to capture versions of members as well as auditing information.
The
first of these statements saves versions of members with TYPE=COBOL
and GROUP=PROD, ignoring differences in columns 1-6 where COBOL sequence
numbers are expected. The second statement saves versions of your
COPYBOOK members, including the non-editable members that might have
been generated as a result of building a BMS member. The third statement
tells SCLM to keep only the latest two versions of your object modules.
This overrides any VERCOUNT specified on the FLMCNTRL macro for the
project. FLMATVER GROUP=PROD,TYPE=COBOL,VERSION=YES,SEQNUM=COBOL
FLMATVER GROUP=PROD,TYPE=COPYBOOK,VERSION=YES
FLMATVER GROUP=PROD,TYPE=OBJ,VERSION=YES,VERCOUNT=2
Note: If
sequence number differences are to be ignored, full length source
lines are saved in the delta file for all lines with non-sequence
number differences, but lines that differ only in the sequence number
are not saved in the delta file. So, when the version is retrieved,
the original sequence numbers for unchanged lines are lost. Instead,
the sequence numbers for the most current version are retained.
This
statement saves only the auditing information for members with TYPE=PASCAL
and GROUP=PROD: FLMATVER GROUP=PROD,TYPE=PASCAL,VERSION=NO
Note: You
can omit the VERSION=NO parameter as it is the default. If omitted,
versions of the member will not be saved.
The order of the
FLMATVER macros is important to keep in mind. Versioning is enabled/disabled
in the order specified, so after turning versioning off for GROUP=*
or TYPE=*, any later FLMATVER macros that specify a particular GROUP
or TYPE will be ignored.
In this example, no version will be
saved for PROJ.AAA.SOURCE. FLMATVER GROUP=*,TYPE=*,VERSION=NO
FLMATVER GROUP=AAA,TYPE=SOURCE,VERSION=YES
However,
if the two statements are reversed, a version of PROJ.AAA.SOURCE will
be saved. FLMATVER GROUP=AAA,TYPE=SOURCE,VERSION=YES
FLMATVER GROUP=*,TYPE=*,VERSION=NO
|