This invocation of CEEPIPI invokes a specified routine as a subroutine.
The common run-time environment identified by token is activated before the called
routine is invoked; after the called routine returns, the environment
is dormant.
The enclave is terminated when an unhandled condition is encountered
or a STOP or EXIT statement (or an exit() function) is executed. (See Stop semantics for more information.) However, the process level
is maintained; only the enclave level terminates.
Syntax
>>-CALL--CEEPIPI--(--call_sub_addr--,--routine_addr--,--token--,-->
>--parm_ptr--,--sub_ret_code--,--sub_reason_code--,------------->
>--sub_feedback_code--)----------------------------------------><
- call_sub_addr (input)
- A fullword function code (integer value = 10) containing the
call_sub request for a subroutine.
- routine_addr (input/output)
- A doubleword containing the address of the routine that should
be invoked. The first fullword contains the entry point address.
Note: - If this is an XPLINK environment and the second fullword is zero,
Preinitialization services will create a new function pointer to call
the routine directly. The new function pointer will be returned in
the second fullword.
- If this is an XPLINK environment and the second fullword is a function
pointer, the XPLINK subroutine is called directly. This fast path avoids
the overhead of translating the routine address to the function pointer.
- token (input)
- A fullword with the value of the token returned by (init_sub)
or (init_sub_dp) when the common run-time environment is initialized. The token must
identify a previously preinitialized environment that is not active
at the time of the call. You must not alter the value of the token.
Note: If the token pointing to the previously preinitialized environment
is a non-XPLINK environment and the subprogram to be invoked is XPLINK,
then a return code of 40 will be returned because this is not valid.
- parm_ptr (input)
- A parameter list pointer or 0 (zero) that is placed in register
1 when the routine is executed.
C and C++ users are advised to
follow the subroutine linkage convention for C/C++ — assembler
ILC applications, as described in z/OS XL C/C++ Programming Guide.
- sub_ret_code (output)
- The subroutine return code. If the enclave is terminated due
to an unhandled condition or a STOP or EXIT statement (or an exit()
function), this contains the enclave return code for termination.
- sub_reason_code (output)
- The subroutine reason code. This is 0 for normal subroutine
returns. If the enclave is terminated due to an unhandled condition
or a STOP or EXIT statement (or an exit() function), this contains
the enclave reason code for termination.
- sub_feedback_code (output)
- The feedback code for enclave termination. This is the CEE000
feedback code for normal subroutine returns. If the enclave is terminated
due to an unhandled condition or a STOP or EXIT statement (or an exit()