z/OS Communications Server: IP User's Guide and Commands
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


Sense codes for special key operation with TELNET

z/OS Communications Server: IP User's Guide and Commands
SC27-3662-00

Table 1 describes the sense codes that are returned with the error messages for special key operations when you are using TELNET.

For information about error messages, see z/OS Communications Server: IP Messages Volume 1 (EZA).

Table 1. Sense codes
Sense code Problem description
8001 The command data length is less than 0 bytes.
8002 There is not enough data in an ERASE/WRITE or an ERASE/WRITE ALTERNATE command.
8003 There is not enough data in A WRITE command.
8004 There is not enough data in A WRITE STRUCTURED FIELD command.
21001 WCC is not a character. The error occurred in a WRITE command.
21002 There is not enough data in a START FIELD subcommand. The error occurred in a WRITE command.
21003 There is not enough data in a START FIELD EXTENDED subcommand. The error occurred in a WRITE command.
21004 There is not enough data in a MODIFY FIELD subcommand. The error occurred in a WRITE command.
21005 There is not enough data in a SET BUFFER ADDRESS subcommand. The error occurred in a WRITE command.
21006 There is not enough data in a REPEAT TO ADDRESS subcommand. The error occurred in a WRITE command.
21007 There is not enough data in an ERASE UNPROTECTED TO ADDRESS subcommand. The error occurred in a WRITE command.
22001 The specified attribute is not a character. The error occurred in a START FIELD subcommand.
22002 A current buffer addressing error occurred. The error occurred in a START FIELD subcommand.
23001 An addressing error for the current buffer occurred. The error occurred in a START FIELD EXTENDED subcommand.
23002 The specified attribute is not a character. The error occurred in a START FIELD EXTENDED subcommand.
23003 The specified attribute is not an acceptable attribute type. The error occurred in a START FIELD EXTENDED subcommand.
24001 A current buffer addressing error occurred. The error occurred in a MODIFY FIELD subcommand.
24002 The specified attribute is not a character. The error occurred in a MODIFY FIELD subcommand.
24003 The specified attribute is not an acceptable attribute type. The error occurred in a MODIFY FIELD subcommand.
25001 The specified address is incorrect. The error occurred in a SET BUFFER ADDRESS subcommand.
26001 A current buffer addressing error occurred. The error occurred in a PROGRAM TAB subcommand.
28001 A current buffer addressing error occurred. The error occurred in a REPEAT TO ADDRESS subcommand.
28002 The specified address is incorrect. The error occurred in a REPEAT TO ADDRESS subcommand.
29001 A current buffer addressing error occurred. The error occurred in an ERASE UNPROTECTED TO ADDRESS subcommand.
29002 The specified address is incorrect. The error occurred in an ERASE UNPROTECTED TO ADDRESS subcommand.
30001 A current buffer addressing error occurred. The error occurred in the Write Data Process.
36001 Another structured field appeared after the READ PARTITION field. The error occurred in a WRITE STRUCTURED FIELD command.
36002 The length is too long or too short in the READ PARTITION field. The error occurred in a WRITE STRUCTURED FIELD command.
36003 A reserved character is incorrect in the READ PARTITION field. The error occurred in a WRITE STRUCTURED FIELD command.
36004 The type is incorrect in the READ PARTITION field. The error occurred in a WRITE STRUCTURED FIELD command.
38001 The length is too long or too short in the ERASE/RESET field. The error occurred in a WRITE STRUCTURED FIELD command.
38002 The Partition ID is incorrect in the ERASE/RESET field. The error occurred in a WRITE STRUCTURED FIELD command.
39001 The length is too long or too short in the SET REPLY mode. The error occurred in a WRITE STRUCTURED FIELD command.
39002 The Partition ID is incorrect in the SET REPLY mode. The error occurred in a WRITE STRUCTURED FIELD command.
39003 The Reply Mode is incorrect in the SET REPLY mode. The error occurred in a WRITE STRUCTURED FIELD command.
40001 The 3270 outbound data stream contains a command that is not in this list.
  • WRITE
  • ERASE/WRITE
  • ERASE/WRITE ALTERNATE
  • ERASE ALL UNPROTECTED
The error occurred in a WRITE STRUCTURED FIELD command.
50001 SO/SI is on longer a pair. SET REPLY mode. The error occurred in the GRFTOMAP Process.

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2013
This information center is Built on Eclipse™ ( www.eclipse.org ).