The requirements for the caller of ESTAEX that are different from ESTAE are:
Environmental factor | Requirement |
---|---|
Cross memory mode: | Any PASN, any HASN, any SASN |
AMODE: | 24- or 31- or 64-bit |
ASC mode: | Primary or access register (AR) |
The caller of ESTAEX cannot have an EUT FRR established.
The parameters on the standard form of the ESTAEX macro are the same as for the standard form of the ESTAE macro, except BRANCH, SVEAREA, and KEY, which are not valid for ESTAEX.
The standard form of the ESTAEX macro is written as follows:
Syntax | Description |
---|---|
name | name: Symbol. Begin name in column 1. |
␢ | One or more blanks must precede ESTAEX. |
ESTAEX | |
␢ | One or more blanks must follow ESTAEX. |
exit addr | exit addr: A-type address, or register (2) - (12). |
0 | |
,CT | Default: CT |
,OV | |
,PARAM=list addr | list addr: A-type address, or register (2) - (12). |
,XCTL=NO | Default: XCTL=NO |
,XCTL=YES | |
,PURGE=NONE | Default: PURGE=NONE |
,PURGE=QUIESCE | |
,PURGE=HALT | |
,ASYNCH=YES | Default: ASYNCH=YES |
,ASYNCH=NO | |
,CANCEL=YES | Default: CANCEL=YES |
,CANCEL=NO | |
,TERM=NO | Default: TERM=NO |
,TERM=YES | |
,RECORD=NO | Default: RECORD=NO |
,RECORD=YES | |
,TOKEN=token addr | token addr: A-type address, or register (2) - (12). |
,RELATED=value | value: Any valid macro keyword specification. |
,SPIEOVERRIDE=NO | Default: SPIEOVERRIDE=NO |
,SPIEOVERRIDE=YES | |
The parameters are explained under the syntax for the standard form of the ESTAE macro.
None.
When control returns to the instruction following the ESTAEX macro, the return code in GPR 15 and the reason code in GPR 0 might be different from those for the ESTAE macro. The following table lists the return and reason codes for ESTAEX.
Hexadecimal Return Code | Hexadecimal Reason Code | Meaning and Action |
---|---|---|
00 | None | Meaning: Successful completion of the ESTAEX
request. Action: None. |
04 | 00 | Meaning: Program error. ESTAEX OV was specified
but ESTAEX CT was performed. No valid ESTAE recovery routine
existed. Action: Correct the environment and either reissue the ESTAEX macro or rerun your program, as appropriate. |
04 | 04 | Meaning: Program error. ESTAEX OV was specified
but ESTAEX CT was performed. The last ESTAE recovery routine
was not owned by the user's RB. Action: Correct the environment and either reissue the ESTAEX macro or rerun your program, as appropriate. |
04 | 08 | Meaning: Program error. ESTAEX OV was specified
but ESTAEX CT was performed. The last ESTAE recovery routine
was not created at the current linkage stack level. Action: Correct the environment and either reissue the ESTAEX macro or rerun your program, as appropriate. |
04 | 0C | Meaning: Program error. ESTAEX OV was specified
but ESTAEX CT was performed. The last recovery routine was
not an ESTAE recovery routine. Action: Correct the environment and either reissue the ESTAEX macro or rerun your program, as appropriate. |
08 | None | Meaning: Program error. The ESTAEX request
was not valid. Action: Correct the request and either reissue the ESTAEX macro or rerun your program, as appropriate. |
0C | None | Meaning: Program error. A recovery routine
address equal to zero was specified, and either
Action: Correct the environment and either reissue the ESTAEX macro or rerun your program, as appropriate. |
10 | None | Meaning: System error. An unexpected error
was encountered while this request was being processed. Action: Rerun your program one or more times. If the problem persists, record the return and reason codes and supply them to the appropriate IBM® support personnel. |
14 | None | Meaning: Environmental error. ESTAEX was
unable to obtain storage for a system data area. Action: Free some storage and reissue the ESTAEX macro. |
18 | None | Meaning: Program error. ESTAEX OV was requested
and one of the following occurred:
Action: Correct the environment and either reissue the ESTAEX macro or rerun your program, as appropriate. |
1C | None | Meaning: Program error. ESTAEX was unable
to access the input parameter list. Action: Make sure the parameter list is contained in the primary address space and reissue the ESTAEX macro. |
20 | None | Meaning: Program error. XCTL=YES was rejected
because the linkage stack was not at the same level as it was when
the RB was created. Action: Correct the environment and either reissue the ESTAEX macro or rerun your program, as appropriate. |
24 | None | Meaning: Program error. A recovery routine
address equal to zero was specified, but it was rejected because no
ESTAE recovery routines were active for the current linkage stack
level. Action: Correct the environment and either reissue the ESTAEX macro or rerun your program, as appropriate. |
28 | None | Meaning: Program error. The caller was
disabled. Action: Correct the environment and either reissue the ESTAEX macro or rerun your program, as appropriate. |
2C | None | Meaning: Program error. The caller was
locked. Action: Correct the environment and either reissue the ESTAEX macro or rerun your program, as appropriate. |
30 | None | Meaning: Program error. The caller had
FRRs on the current FRR stack. Action: Correct the environment and either reissue the ESTAEX macro or rerun your program, as appropriate. |
34 | None | Meaning: Program error. The caller was
in SRB mode. Action: Correct the environment and either reissue the ESTAEX macro or rerun your program, as appropriate. |
ESTAEX addr,PARM=parmaddr,TERM=YES,SPIEOVERRIDE=YES