When you validate your SCDS, you verify that all classes and groups
assigned by your ACS routines are defined in the SCDS. To validate
the SCDS:
- Enter an 8 (Control Data Set) on the ISMF Primary
Option Menu to display the CDS Application Selection panel, shown
in Figure 1.
Figure 1. Specifying the SCDS Base Configuration Panel Utilities Help
------------------------------------------------------------------------------
CDS APPLICATION SELECTION
Command ===>
To Perform Control Data Set Operations, Specify:
CDS Name . . MYSCDS
(1 to 44 Character Data Set Name or 'Active')
Select one of the following Options:
1. Display - Display the Base Configuration
2. Define - Define the Base Configuration
3. Alter - Alter the Base Configuration
4. Validate - Validate the SCDS
5. Activate - Activate the CDS
6. Cache Display - Display CF Cache Structure Names for all CF Cache Sets
7. Cache Update - Define/Alter/Delete CF Cache Sets
8. Lock Display - Display CF Lock Structure Names for all CF Lock Sets
9. Lock Update - Define/Alter/Delete CF Lock Sets
If CACHE Display is chosen, Enter CF Cache Set Name . . *
If LOCK Display is chosen, Enter CF Lock Set Name . . . *
(1 to 8 character CF cache set name or * for all)
Use ENTER to Perform Selection;
Use HELP Command for Help; Use END Command to Exit.
- In the CDS Name field, type in the name of the SCDS that is to
contain the base configuration. The CDS name must be the same name
that you previously used for the SCDS. In this example, the CDS name
is YOUR.OWN.SCDS.
Enter a 4 (Validate) to view the Validate ACS
Routines or Entire SCDS panel, shown in Figure 2.
Figure 2. Validating the SCDS Panel Utilities Help
------------------------------------------------------------------------------
VALIDATE ACS ROUTINES OR ENTIRE SCDS
Command ===>
To Perform Validation, Specify:
SCDS Name . . . . . 'YOUR.OWN.SCDS'
(1 to 44 Character Data Set Name)
ACS Routine Type . . * (DC=Data Class, MC=Management Class, SC=Storage
Class, SG=Storage Group, *=Entire SCDS)
Listing Data Set . . VALIDATE.ERROR.LISTING
(1 to 44 Character Data Set Name)
Use ENTER to Perform Validation;
Use HELP Command for Help; Use END Command to Exit.
- In the SCDS Name field, specify the name of your SCDS. Enter an
asterisk in the ACS Routine Type field to validate the entire SCDS.
You can save a listing of the validation results by specifying
a sequential data set name or partitioned data set member in the Listing
Data Set field. If you leave this field blank, no listing is generated,
so you do not see possible errors.
You receive warning messages
from the VALIDATE command if there are classes defined in your SCDS
that are not assigned in your ACS routines.
If you have storage
groups defined in your SCDS that are not assigned in your ACS routines,
you receive messages from VALIDATE and your SCDS is marked invalid.