Explanation
System management facilities (SMF) encountered
an error while attempting to write an SMF record.
Register 15
contains a hexadecimal reason code that explains the error:
- Code
- Explanation
- 04
- GETMAIN failure.
System Action: The SMFEWTM or SMFWTM
request fails and SMF continues processing.
Operator Response: Notify
the system programmer.
System Programmer Response: It
is likely the SMFEWTM or SMFWTM caller is experiencing storage problems.
Check for an ABEND878 or other prior virtual storage abends, and follow
the recommended actions accordingly.
- 09
- IXGWRITE failure. The IXGWRITE operation used for writing a block
of data to the logstream failed because of an internal error. For
this error, registers 2 and 3 contain the return and reason codes
that were returned following the IXGWRITE operation. The IXGWRITE
return and reason codes are described in z/OS MVS Programming: Assembler Services Reference IAR-XCT.
System
Action: SMF disconnects the log stream that was to receive the
data at the time when the failing IXGWRITE was issued. SMF processing
continues, and the data that SMF collects that are directed to be
written to the now disconnected log stream are buffered until the
log stream is connected.
Operator Response: Notify the
system programmer.
System Programmer Response: Search
problem reporting databases for a fix for the problem. If no fix exists,
capture the dump and report the problem to the IBM® support center.
- 101-111
- Error in IFASEXIT processing. For all of these error codes:
System
Action: IFASEXIT processing is discontinued for the current SMF
record.
Operator Response: Notify the system programmer.
System
Programmer Response: Search problem reporting databases for a
fix for the problem. If no fix exists, capture the dump and report
the problem to the IBM support
center.
- 101
- IFASEXIT failed to establish recovery.
- 102
- Incorrect input parameter list.
- 103
- Failure obtaining storage for IFASXCB.
- 104
- Failure obtaining storage for IFASXCBG.
- 105
- Failure obtaining storage for the log stream block (buffer).
- 106
- OPEN validation error because the IFASXCB token area is not correct.
- 108
- Error on browse option because of incomplete browse parameters.
- 110
- IFASXGET input event error.
- 111
- IFASXGET browse session was not established.
Source
System Management Facilities (SMF)