You need to know how to access the following: - SVC dump, SYSMDUMP, and transaction dump
- Software record in SYS1.LOGREC from the time frame of the error.
If an SVC dump was taken for the error as indicated by
IEA794I, IEA611I or IEE911E, use the following IPCS commands to format
information and extract the abend and reason code (when available). - IPCS STATUS FAILDATA
For the abend code, look for AB/S0hhh
in the symptoms under the heading SEARCH ARGUMENT ABSTRACT, if present.
For the reason code, look for PRCS/hhhhhhhh in the symptoms, or look
in the register indicated in the abend code explanation.
Not
every dump has error information associated with it. Some dumps, like
those requested through the SLIP or DUMP command will not have STATUS
FAILDATA output. There are occasions when STATUS FAILDATA will not
provide the information you need. Check SYSTRACE and SUMMARY FORMAT
(look for RTM2WA SUMMARY) for the abend. If you cannot find it, the
dump was probably not requested for an abend. Check the dump title
(L Title) and determine why it was not requested. Also, check SYS1.LOGREC,
and the SYSLOG and job log for the time frame of the dump.
In
the following example, fields AB/S005C and PRCS/00000214 indicate
what to extract for the abend and reason code. The free-format search
argument is: ABEND05C and RSN00000214. * * * DIAGNOSTIC DATA REPORT * * *
SEARCH ARGUMENT ABSTRACT
RIDS/IEFW21SD#L RIDS/#UNKNOWN AB/S005C PRCS/00000214 REGS/0E01E REGS/0C6D8
Symptom Description
------- -----------
RIDS/IEFW21SD#L Load module name: IEFW21SD
RIDS/#UNKNOWN Csect name: #UNKNOWN
AB/S005C System abend code: 005C
PRCS/00000214 Abend reason code: 00000214
REGS/0E01E Register/PSW difference for R0E: 01E
REGS/0C6D8 Register/PSW difference for R0C: 6D8
SERVICEABILITY INFORMATION NOT PROVIDED BY THE RECOVERY ROUTINE
Program id
Recovery routine csect name
Recovery Routine Label
Date Assembled
Module Level
Subfunction
Time of Error Information
PSW: 071C2000 83AA2110 Instruction length: 02 Interrupt code: 000D
Failing instruction text: BFFFB148 0A0D98EC B08807FE
Breaking event address: 00000000_00000000
AR/GR 0-1 00000000/00000001_00000000 00000000/00000000_0405C000
AR/GR 2-3 00000000/00000000_7F10C128 00000000/00000000_00000024
AR/GR 4-5 00000000/00000000_006EA338 00000000/00000000_006A3648
AR/GR 6-7 00000000/00000000_006A2D64 00000000/00000000_7F363028
AR/GR 8-9 00000000/00000000_00000000 00000000/00000000_00000000
In the following STATUS FAILDATA output,
the symptom string indicates a system abend code of X'0C4' with
a reason code of X'00000010' SEARCH ARGUMENT ABSTRACT
PIDS/5752SCPX1 RIDS/BPXINPVT#L RIDS/BPXVFPCT AB/S00C4 PRCS/00000010
REGS/C4E10 RIDS/BPXMIPCE#R
Symptom Description
------- -----------
PIDS/5752SCPX1 Program id: 5752SCPX1
RIDS/BPXINPVT#L Load module name: BPXINPVT
RIDS/BPXVFPCT Csect name: BPXVFPCT
AB/S00C4 System abend code: 00C4
PRCS/00000010 Abend reason code: 00000010
REGS/C4E10 Register/PSW difference for R0C:-4E10
RIDS/BPXMIPCE#R Recovery routine csect name: BPXMIPCE
OTHER SERVICEABILITY INFORMATION
Recovery Routine Label: BPXMIPCE
Date Assembled: 12/19/04
Module Level: HBB7720
Subfunction: OpenMVS
Time of Error Information
PSW: 47043000 80000000 00000000 27EA624C
Instruction length: 02 Interrupt code: 0010
Failing instruction text: 58E0D56C 18F10E0E B2190200
Translation exception address: 00000000_66831000
- EREP or VERBX LOGDATA
Use EREP to format software records
(TYPE=S) recorded to SYS1.LOGREC for the time frame of the failure
or error or format SYS1.LOGREC records from the in storage buffer
using the VERBX LOGDATA command.
For information about
EREP, see EREP Reference.
To find software records that might be associated with the failure,
follow these suggestions: - Look for the general time frame
- Search on the job name or ASID involved
- Search for the failing component id.
For the abend code, look for AB/S0hhh in the symptoms
under the heading SEARCH ARGUMENT ABSTRACT, if present.
For
the reason code, look for PRCS/hhhhhhhh in the symptoms, or look in
the register indicated in the abend code explanation.
Here
is an example of a software logrec entry formatted by EREP or the
IPCS VERBX LOGDATA command against an SVC dump. The free-format
search argument generated for this entry is: ABEND05C RSN00000214. TYPE: SOFTWARE RECORD REPORT: SOFTWARE EDIT REPORT DAY.YEAR
(SVC 13) REPORT DATE: 115.06
FORMATTED BY: IEAVTFDE HBB7703 ERROR DATE: 096.06
MODEL: 2084 HH:MM:SS.TH
SERIAL: 0D8B9F TIME: 12:14:42.66
JOBNAME: HSMVM0A SYSTEM NAME: VM0A
ERRORID: SEQ=03567 CPU=0000 ASID=003C TIME=12:14:42.6
SEARCH ARGUMENT ABSTRACT
PIDS/5752SC1B4 RIDS/IEFW21SD#L RIDS/IEFDB400 AB/S005C PRCS/00000214 REGS/0E01E
REGS/0C6D8 RIDS/IEFDB402#R
SYMPTOM DESCRIPTION
------- -----------
PIDS/5752SC1B4 PROGRAM ID: 5752SC1B4
RIDS/IEFW21SD#L LOAD MODULE NAME: IEFW21SD
RIDS/IEFDB400 CSECT NAME: IEFDB400
AB/S005C SYSTEM ABEND CODE: 005C
PRCS/00000214 ABEND REASON CODE: 00000214
REGS/0E01E REGISTER/PSW DIFFERENCE FOR R0E: 01E
REGS/0C6D8 REGISTER/PSW DIFFERENCE FOR R0C: 6D8
RIDS/IEFDB402#R RECOVERY ROUTINE CSECT NAME: IEFDB402
OTHER SERVICEABILITY INFORMATION
RECOVERY ROUTINE LABEL: IEFAB4ED
DATE ASSEMBLED: 05223
MODULE LEVEL: UA20441
SUBFUNCTION: DYNAMIC ALLOCATION
TIME OF ERROR INFORMATION
PSW: 071C2000 83AA2110 INSTRUCTION LENGTH: 02 INTERRUPT CODE: 000D
FAILING INSTRUCTION TEXT: BFFFB148 0A0D98EC B08807FE
REGISTERS 0-7
GR: 00000000 0405C000 7F10C128 00000024 006EA338 006A3648 006A2D64 7F363028
- OPERLOG, SYSLOG, or job log or VERBEXIT MTRACE
Look
for message IEA995I or other messages with an abend code in the message
text. The message might also give a reason code. For example: IEA995I SYMPTOM DUMP OUTPUT 694
USER COMPLETION CODE=4039 REASON CODE=00000000
TIME=05.07.41 SEQ=33565 CPU=0000 ASID=0247
PSW AT TIME OF ERROR 078D1000 99937C66 ILC 2 INTC 0D
ACTIVE LOAD MODULE ADDRESS=1987A4C0 OFFSET=000BD7A6
NAME=CEEPLPKA
DATA AT PSW 19937C60 - 00181610 0A0D58D0 D00498EC
AR/GR 0: 80C4BB3E/84000000 1: 00000000/84000FC7
2: 00000000/000A1E08 3: 00000000/0002000D
4: 00000000/1992CA78 5: 00000000/000A1954
6: 00000000/00000000 7: 00000000/198758E0
8: 00000000/000A1E08 9: 00000000/000A34C6
A: 00000000/000A1954 B: 00000000/19937B90
C: 00000000/0009EA58 D: 00000000/000A4608
E: 00000000/9992BBAE F: 00000000/00000000
END OF SYMPTOM DUMP
In message texts, an abend code can be called
a system completion code or a SYS CODE. A message can
show an abend code in the variable text without identifying it as
an abend code; use the message explanation to understand the variable
text.
- VERBEXIT SYMPTOM output from a dump: Format the
dump completely, as described in step 1 of Gathering additional problem data for abends. Look for AB/S0hhh and PRCS/hhhhhhhh
in the symptoms.
In the following VERBEXIT SYMPTOM output, the
primary symptom string indicates a system abend code of X'03C' and
a return code of X'2D000810'. Primary Symptom String:
RIDS/NUCLEUS#L RIDS/IARYTASS PIDS/5752SC1CR AB/S003C RIDS/IARRR#R
VALU/HC0099680 REGS/0E0B4 REGS/088FA PRCS/2D000810 VALU/CNAGEMENT
Symptom Symptom data Explanation
--------------- ------------- -----------
RIDS/NUCLEUS#L NUCLEUS#L Routine identifier
RIDS/IARYTASS IARYTASS Routine identifier
PIDS/5752SC1CR 5752SC1CR Component identifier
AB/S003C 003C ABEND code - system
RIDS/IARRR#R IARRR#R Routine identifier
VALU/HC0099680 C0099680 Error related hexadecimal value
REGS/0E0B4 0E0B4 Program register
REGS/088FA 088FA Program register
PRCS/2D000810 2D000810 Return code
VALU/CNAGEMENT NAGEMENT Error related character value
The dump does not contain a secondary symptom string.
- Dump title
Look at the dump title; some titles contain
the abend and reason codes. Use the DISPLAY DUMP,TITLE or DISPLAY
DUMP,ERRDATA to display the dump title and any error information
associated with captured dumps, or dumps written to pre-allocated
or dynamically allocated data sets. In response to the DISPLAY command,
message IEE853I or IEE854I are issued containing the requested information.
Look in the IEE853I or IEE854I message replies for the abend code,
reason codes and the registers. For example: IEE853I 12.54.26 SYS1.DUMP TITLES 939
SYS1.DUMP DATA SETS AVAILABLE=000 AND FULL=002
CAPTURED DUMPS=0000, SPACE USED=00000000M, SPACE FREE=00000200M
DUMP00 TITLE=ABEND=S0C4,RC=0010,COMPON=SDSF-ESTAE,COMPID=5647-A01
,ISSUER=ISFSTAE,SDSF ABEND ROUTINE
DUMP TAKEN TIME=17.49.48 DATE=nn/nn/nnnn
DUMP01 TITLE=ABEND=S0C4,RC=0010,COMPON=SDSF-ESTAE,COMPID=5647-A01
,ISSUER=ISFSTAE,SDSF ABEND ROUTINE
DUMP TAKEN TIME=nn.nn.nn DATE=nn/nn/nnnn
For a dump that has been
copied from the SYS1.DUMPxx data set or for an SVC dump you are viewing
in IPCS, use the IPCS LIST TITLE subcommand to obtain the dump
title.
You know you are done when you locate the abend and reason
codes. Look up a description of the abend code using the product documentation
or LookAt and follow the recommendations.
|