Examples

  1. At the NetView console entering:
    MVS F NETEVE2E,DISPLAY,STATUS                 
    displays information as shown in Figure 1.
    Figure 1. Event/automation service STATUS information
    IHS0141I SERVICE   STATUS    ADDITIONAL INFO  
    IHS0142I -------   ------    ---------------  
    IHS0143I ALERTA    DOWN      connection idle  
    IHS0143I MESSAGEA  UP        *                
    IHS0143I EVENTRCV  DOWN      *                
    IHS0143I TRAPALRT  DOWN      *                
    IHS0143I ALRTTRAP  DOWN      *                
    IHS0143I PPI       UP        INGEVE2E          
    IHS0143I TCP/IP    UP        9.152.87.64      
  2. At the NetView console entering:
    MVS F NETEVE2E,DISPLAY,QSTATS
    displays information as shown in Figure 2. You can use this to find out where the event flow has broken down.
    Figure 2. Event/automation service QSTATS information
    IHS0145I TASK      QCOUNT      TOTAL SENT  TOTAL RCVD 
    IHS0146I ----      ------      ----------  ---------- 
    IHS0147I CONTROL   0           23          0          
    IHS0147I ALERTA    0           23          0          
    IHS0147I MESSAGEA  0           0           23         
    IHS0147I EVENTRCV  0           0           0          
    IHS0147I TRAPALRT  0           0           0          
    IHS0147I ALRTTRAP  0           0           0