Step 3D: Update LPALSTxx
About this task
| SysOps | ProcOps |
|---|---|
| ✓ | ✓ |
Edit the LPALSTxx member to add ING.SINGLPA to the SA z/OS load library. There is no other choice for this library, it must be in the LPALST concatenation.
You can avoid an IPL: Because ING.SINGLPA contains only a
few modules, you can also code a PROGxx member that enables a dynamic
addition of those modules to the LPALST. If you do this, no IPL is required. For a complete
description of dynamic LPA and PROGxx, see z/OS MVS Initialization and Tuning Reference.
Notes:
- Make sure that the SA z/OS load library is cataloged in the master catalog, or copy the members in ING.SINGLPA to a data set that is in the master catalog.
- Be sure you do not have any data sets containing load modules with prefixes of AOF, ISQ, ING, or HSA in these members.
- If ING.SINGLPA is to be placed in SYS1.PARMLIB member LPALSTxx, ensure the data set organization is of type PDS.