Output

The first record in the data set is a title record that describes each column. The remaining records are the data records. One data record is written for each type 114 SMF record.

Table 1 describes the format of each record.
Table 1. Format of INGPUSMF Utility Data Set Records
Column Description
1 SMF system ID
2 Date when SMF record was written, in YYYYMMDD format
3 Time when SMF record was written, in hhmmss format
4 SA z/OS product name, including release level
5 Name of sysplex
6 System name
7 NetView domain ID
8 XCF group name
9 Resource name in automation manager notation
10 Job name, if present
11 Event
12 Automation agent status
13 Startup time in seconds
14 Active time in seconds
15 Shutdown time in seconds
16 Down time in seconds
17 Start type
18 Stop type
19 Termination (abend) code

The termination code for APGs can have the string $UNPL, which means unplanned termination of an APG resource.