Figure 1 shows the policy items that are displayed when a new MVSCOMP Defaults entry is defined or when existing MVSCOMP Defaults entry is selected from the Entry Name Selection panel.

Figure 1. Policy Selection Panel for MVSCOMP Defaults
   ACTIONS  HELP
 ------------------------------------------------------------------------------
 AOFGEPOL                        Policy Selection                    Row 1 of 7
 Command ===>                                                  SCROLL===> PAGE
 
 Entry Type : MVSCOMP Defaults      PolicyDB Name   : USER_PDB     
 Entry Name : MVSCOMP_DFLTS_NAME    Enterprise Name : USER_ENTERPRISE
 
 Action      Policy Name          Policy Description
             DESCRIPTION          Enter description
             MVSESA INFO          Define MVS component information defaults
             AUTOMATION FLAGS     Define MVS component automation flags default
             THRESHOLDS           Define MVS component thresholds defaults
             -------------------- ---------------------------------------------
             WHERE USED           List systems linked to this entry
             COPY                 Copy data from an existing entry

The unique policy items for MVSCOMP Defaults are:

MVSESA INFO
This option allows you to specify a captured messages limit as the maximum number of messages that will be captured for each MVSESA resource while SA z/OS is running. These messages will show up in the SA z/OS command DISPSYS. If the field is left blank the value can be inherited from the system defaults definition. If neither of them is specified, a default value of 0 is used.

You can use the Inform List field to specify where each MVSESA resource is registered to and who all status changes are propagated to. Valid values are SDF, EIF, E2E, IOM, ITM, TTT and USR. You can specify one or more values. If the field is left blank the value can be inherited from the systems default definition. If the resource should not be registered at all, specify NONE. This will prevent inheritance from systems default definitions. If nothing is specified, no status changes are propagated. If E2E is specified, the resources will be shown on the e2e domain view. This applies only to resources that are directly attached to a system or sysplex. For others, the specification will be ignored.

AUTOMATION FLAGS
This option allows you to specify automation settings that will be used as defaults for MVS Components. The settings specified here will be used if you do not provide specific automation settings for MVS Components. See the section SA z/OS Automation Flags in IBM Z® System Automation User's Guide for more information about setting automation flags.
THRESHOLDS
This policy item is used to set default error thresholds for MVS Components. The settings specified here will be used if you do not provide specific thresholds for MVS components. See the section How SA z/OS Uses Error Thresholds in IBM Z System Automation User's Guide for more information about error thresholds.