MVS Component Entry Type
This entry type allows you to apply automation to various z/OS data sets, resources and facilities, which are referred to as MVS components.
You can set error thresholds and automation flags for the following MVS components:
- MVSDUMP (SYS1.DUMP00–xx)
- SMFDUMP (SYS1.MANx)
- LOGREC (SYS1.LOGREC)
- SYSLOG (SYS1.SYSLOG.INDX)
In addition, you can customize the recovery procedure that is used for a WTOBUF overflow and automate responses to messages that are issued for MVS components.
Figure 1 is displayed when you select MVS Component from the Entry Type Selection menu.
COMMANDS ACTIONS VIEW HELP
------------------------------------------------------------------------------
AOFGENAM Entry Name Selection Row 1 to 2 of 2
Command ===> SCROLL===> PAGE
Entry Type : MVS Component PolicyDB Name : USER_PDB
Enterprise Name : USER_ENTERPRISE
Action Entry Name Short Description
+SA_PREDEFINED_MSGS Messages predefined by SA for AT build
MVS_COMPONENTS MVS Components used in all systems
On top of the list there is a special entry +SA_PREDEFINED_MSGS, followed by the user defined entries. This special entry is described in detail in Predefined SA z/OS Messages of Automation Table, Message Revision Table, and MPFLSTxx member.