ING235W No information from automation manager. event event not created for consumer.

Explanation

An error occurred when requesting information from the automation manager that needed to be included in a domain event. The event has not been created.

  • The variable event specifies the event to be created. Possible values are: READY, REFRESH, CHANGE.

    A READY event is created at initialization time of the automation domain and after having recovered from miscellaneous error situations.

    A REFRESH event is created after having refreshed the configuration policy.

    A CHANGE event is created after a takeover of the automation manager if the outage has not exceeded a given time interval.

  • The variable consumer shows the name of the event consumer that the event should have been forwarded to.

System action

Processing of the event is stopped.

Operator response

None.

System programmer response

Analyze the NetView log for further SA z/OS® messages concerning the communication between the primary agent and the automation manager.