ISQXIII
Purpose
The ISQXIII command initializes (or re-initializes) a target system, or a target system connection. When initializing a target system, ISQXIII establishes a connection to the target processor and enables its console connections.
When initializing a target hardware, ISQXIII establishes a connection to the target processor and enables the console connection for all target systems defined that run on the specified target hardware.
Syntax
Requirements
The requirements for this command to complete successfully are:
- Processor operations must be active.
- The addressed target system must have a status of UNKNOWN or CLOSED.
- The addressed target system must be initialized if you use the target_system_ProcOps_nameconsole_designator syntax.
Parameters
- target_system_ProcOps_name
- Is the name of the target system. This is a required parameter,
and must be a valid target system name.
- OC
- Specifies the active operator console (not valid for the coupling facility).
- SC
- Specifies the system console connection.
- target_hardware_ProcOps_name
- Is the name of the target hardware. This is a required parameter, and must be a valid target hardware name.
Defaults
None.
Usage
Issue the ISQXIII command to a target system to prepare it for processor operations monitoring and control.
Issue the ISQXIII command to a target hardware to prepare it and all defined target systems for processor operations monitoring and control.
Restrictions and Limitations
The following restrictions or limitations apply:
- To re-initialize a target system, you must first close it with the ISQXCLS command (see ISQXCLS).
- To initialize a console connection, the target system must have been initialized previously.
Return Codes
- 0
- The ISQXIII command processed successfully and the processor operations environment for the specified target system has been initialized or re-initialized.
- 4
- During initialization of a target system, one or more of the following problems
occurred:
- No system consoles could be contacted.
- No operator consoles could be contacted.
- 8
- You used syntax that is not valid, specified a target system that is not initialized.
- 12
- An internal error occurred or connection path status is SUSPENDED to the processor hardware (SE/HMC).
- 16
- A severe error occurred.
- 32
- The processor operations environment does not exist; the ISQXIII command was not processed.