Policy Definitions for Message Limits

SA z/OS allows you to limit the number of messages that can be captured for an individual automation resource (APL, MTR), MVS component defaults (MDF), system defaults (SDF), or application defaults (ADF). In absence of a custom default value, that limit is zero.

To set the captured message limit, specify a value in the Captured Messages Limit field in the following policy items respectively.
  • To set the limit for an individual APL instance or class, use the APPLICATION INFO Policy Item for Applications (APL).
  • To set the limit for an individual MTR, use the MONITOR INFO Policy Item for Monitor Resources (MTR).
  • To set the default limit for resource MVSESA, use the MVSESA INFO policy item for MVSCOMP Defaults (MDF).
  • To set the default limit for a system, use the AUTOMATION OPTIONS Policy Item for System Defaults (SDF).
  • To set the default limit for all APLs, use the policy item for Application Defaults (ADF).

Exceptional messages have their own limit that can be specified by setting the Exceptional Messages Limit field in the AUTOMATION OPTIONS policy item for System Defaults (SDF). The default is 300.

 ------------------------------------------------------------------------------
                             System Automation Options                         
                                                                               
 Entry Type : System Defaults       PolicyDB Name   : MYPDF                    
 Entry Name : SYSTEM_DEFAULTS       Enterprise Name : MYPDF                    
                                                      
 System specific definitions:                                                  
   Exceptional Messages Limit . 300       (0 to 99999999, default 300)         
   IPL Complete Time Limit. . .           (00:00:00 to 24:00:00)               
   IPL Complete Status  . . . .                                                                          
                                          (AVAILABLE SOFTDOWN STANDBY)         
                                          (or SATISFACTORY)                    