User Exits for CONVERT Processing
Two user exits are implemented for the CONVERT processing.
- INGEX07: This is called before the CONVERT process starts. No parameters are passed.
- INGEX08: This is called after the CONVERT process has ended. No parameters are passed.
If user exit INGEX07 produces return code RC = 0, the CONVERT processing continues. If a return code RC > 0 is produced, an error message is displayed, the CONVERT function does not start and the processing terminates.
If user exit INGEX07 ended with a return code RC > 0, user exit INGEX08 is not called because the CONVERT processing will terminate.
User exit INGEX08 is always called once the CONVERT function has started.
If user exit INGEX08 produces a return code RC > 0, an error message is displayed.