INGEVENT
Purpose
The INGEVENT command sets or resets a particular event for all affected resources in a sysplex, or for specific resources.
Syntax
Parameters
- event
- Specifies the name of the event.
- REQ
- Specifies the request to be performed. It can have the following
values:
- SET
- Sets the event for all resources having the event defined.
- RESET|UNSET
- Resets or unsets the event for all resources having the event
defined.
Note that RESET and UNSET are synonyms.
- RESOURCE
- Specifies the name of the resource where INGEVENT should be effective. It can be abbreviated to RES. The format is name/type[/system]
- TARGET
- For information on the TARGET parameter, see TARGET Parameter.
- WAIT
- Specifies whether or not to wait until the request is complete.
The default is YES.
nnn is the number of seconds to wait before giving up and reporting that a timeout has occurred. The maximum time interval is 999 seconds.
Restrictions and Limitations
Wildcards are not supported.
Usage
The INGEVENT command operates sysplexwide. For an overview see Overview of Commands that Operate Sysplexwide.
Examples
To set an event for all resources
that are linked to that event, type the following:
INGEVENT B000P100 REQ=SETThe
command response is as follows:
IPUFA AOF442I SET EVENT B000P100 DONE FOR RESOURCE */*/* ON AOCPLEX. -
FROM=AOCA
IPUFA AOF099I FUNCTION COMPLETED