EP/Local errors not being recorded
EP/local errors are not being recorded at the hardware monitor database.
If EP/local errors are not being recorded at the hardware monitor
database, take the following actions:
- Use the NetView® command LIST STATUS=TASKS to ensure that BNJMNPDA is an active task. Start the task if it is not active. Also, determine whether a task abend was recorded at the time the error should have been recorded.
- Ensure that recording filters have not been set to block these records from being recorded.
- Determine whether any errors are being recorded.
- Check SYS1.LOGREC to determine if the error is recorded there. If the error is not recorded, this is not a hardware monitor defect.
If you follow the preceding steps and do not identify your problem,
document it in the following way:
- Obtain the following documentation:
- Listings of the CNMSTYLE member for NetView installation.
- Data from SYS1.LOGREC for the error in question.
- The network log and the NetView trace from the time of the failure.
- Follow the instructions in Classifying problems and Documenting and reporting problems before contacting IBM® Software Support.
| For information about: | Refer to: |
|---|---|
| Task statement | IBM Tivoli® NetView for z/OS® Installation: Configuring Additional Components |