In the Z Common Data Provider
Configuration Tool, after you define a data stream for z/OS®
log data (which is gathered by the Log Forwarder), use the LOG FORWARDER
button to set the configuration values for your Log Forwarder.
Procedure
To define your global Log Forwarder configuration values, complete the following
steps:
-
In the Global Properties section of the Policy Profile Edit window, click
LOG FORWARDER.
-
In the
Configure Log Forwarder properties
window, update the
configuration values, and click OK.
- Discovery Interval
- In the process of streaming data, the number of minutes that the Log Forwarder waits before it checks for
a new log file in the data stream. This value applies to all data streams from the Log Forwarder, although it can be
overridden on some individual streams.
The value must be an integer in the range 0 - 1440. A value
of 0 specifies that the Log Forwarder only checks for a new log file once when the data gatherer is
started. The default value is 1.
- Pattern Discovery Interval
- In the process of streaming data, the number of minutes that the Log Forwarder waits before it checks for new data
sources that match wildcard specifications. This value applies to all job log data streams from the
Log Forwarder.
The value must
be an integer in the range 0 - 1440. The default value is 1.