HBOG030E The System Logger service system_service completed with a non-zero return and reason code. The Operlog gatherer will terminate. Log stream: log_stream_name Return Code:return code Reason Code:reason code Diag Code 1:diag1 Diag Code 2:diag2 Diag Code 3:diag3 Diag Code 4:diag4
Explanation
The System Logger service request completed with the listed return code/reason code. These diagnostic codes indicate that a severe error has occurred while accessing the System Logger service. The Operlog gatherer will terminate as a result.
The System Logger services that can be appear in this message are:
- IXGCONN CONNECT
- IXGCONN DISCONNECT
- IXGBRWSE REQUEST=START
- IXGBRWSE REQUEST=END
- IXGBRWSE REQUEST=READCURSOR
Response
Review the corresponding System Logger service Return and reason codes documentation for more information on the diagnostic codes.