HBO1552E The Data Collector cannot read progress information from the file with path name file_pathname.

Explanation

The Data Collector records its progress when reading log data so when it is restarted, it can resume at the point where it previously stopped. This process ensures that no log data is missed even if the Data Collector is stopped. A file with the specified path name exists, but an I/O error occurred when the Data Collector was trying to read progress information from this file.

Response

Review the Data Collector job log to determine the cause, correct the problem, and then restart the Data Collector.

If you manually delete the file and restart the Data Collector, the Data Collector can not resume log data collection at the point where it previously stopped. Instead, it starts to collect log data anew, at the time that it starts.