EEWN0070 - EEWN0120

EEWN0070E

The connection to the server "server" for user "user" has failed.

Explanation

The connection to the PeopleSoft application server could not be made or has failed. This can be due to any of the following reasons:

  • The PeopleSoft user ID, or its password, or both, are incorrectly specified in the options file
  • The PeopleSoft application server IP address or host name, or its port number, or both, are incorrectly specified in the options file
  • The PeopleSoft application server refused the connection.
  • A network failure occurred.

System action

The PeopleSoft process cannot be submitted and monitored.

Operator response

Verify that the values in the options file for the PeopleSoft user, its encrypted password, the application server address, and the application server port are correct.

If the option values are correct, then analyze the PeopleSoft application server log for the failed connection attempt.

When you have found the problem, correct it and retry the operation.

EEWN0100W

Option "lower_option(lower_option_value)" must have a value not greater than option "higher_option(higher_option_value)".

Explanation

See message.

System action

The program continues, using the default values for these options.

Operator response

If you do not want to use the default values, stop the program, change the options so that the value of the lower_option is not greater than the value of the higher_option, and restart the program.

EEWN0101W

Option "option(value)" is not a positive value.

Explanation

The indicated option must have a positive value.

System action

The program continues, using the default values for this option.

Operator response

If you do not want to use the default values, stop the program, change the option to a positive value and restart the program.

EEWN0102W

Option "option(value)" is greater than the maximum value allowed (maximum_value).

Explanation

See message.

System action

The program continues, using the default values for this option.

Operator response

If you do not want to use the default values, stop the program, change the option to a value not greater than the maximum allowed, and restart the program.

EEWN0104E

The method failed to submit and monitor the PeopleSoft process to completion due to a connection failure.

Explanation

See message.

System action

The IBM Workload Scheduler job is put into the "abend" status.

Operator response

Check the values of the options that define the connection (application server name or IP address, application server port, user ID, and password). If the values are correct, check if there were network failures at the time of the submission. When you have identified and fixed the problem, run the IBM Workload Scheduler job again.

EEWN0105E

The process submission failed due to a conflict in the PeopleSoft database. The submission was tried number_of_tries times.

Explanation

The access method was unable to submit the PeopleSoft process. No further submission attempts will be made because the maximum number of retries (tws_retry option value) has been reached. The error was due to an unmanaged conflict between concurrent database save operations in PeopleSoft. This might occur when several IBM Workload Scheduler jobs submit the same PeopleSoft process, and that process uses inline bind variables.

System action

The PeopleSoft process could not be submitted. The IBM Workload Scheduler job is put into the "abend" status.

Operator response

Rerun the IBM Workload Scheduler job. If the problem persists, contact Software Support for assistance.

EEWN0106E

The process submission has failed for an unknown reason.

Explanation

See message.

System action

The IBM Workload Scheduler job is put into the "abend" status.

Operator response

Check the IBM Workload Scheduler job definition. Check that all parameters are correct and that the referred objects all exist. Retry the operation. If the problem persists, contact Software Support for assistance.

EEWN0107E

The monitoring of the PeopleSoft process has failed.

Explanation

See message.

System action

The IBM Workload Scheduler job is put into the "abend" status.

Operator response

Monitor the PeopleSoft process in the PeopleSoft Process Monitor page.

EEWN0110W

The process submission has failed due to a conflict in the PeopleSoft database. The submission is retried until the maximum number of retries is reached.

Explanation

See message.

System action

The program tries to resubmit the PeopleSoft process until the maximum number of retries is reached (the value of the tws_reply option).

Operator response

None.

EEWN0111E

The submission, control, or monitoring of the PeopleSoft process has failed for an unknown reason. The access method does not attempt to resubmit it.

Explanation

See message.

System action

The IBM Workload Scheduler job is put into the "abend" status.

Operator response

Retry the operation. If the problem persists, contact Software Support for assistance.

EEWN0112E

The process submission attempt failed due to a possible connection failure.

Explanation

See message.

System action

The IBM Workload Scheduler job is put into the "abend" status.

Operator response

Check the values of the options that define the connection (application server name or IP address, application server port, user ID, and password). If the values are correct, check if there were network failures at the time of the submission. When you have identified and fixed the problem, run the IBM Workload Scheduler job again.

EEWN0113W

The attempt to monitor the progress of the PeopleSoft job has failed. The attempt is retried until the maximum number of retries is reached.

Explanation

See message.

System action

The program tries to monitor the PeopleSoft process until the maximum number of retries is reached (the value of the tws_reply option).

Operator response

None.

EEWN0119E

The retrieved run status (status) has an incorrect format.

Explanation

See message.

System action

The IBM Workload Scheduler job is put into the "abend" status.

Operator response

Resubmit the PeopleSoft process. If the problem persists, contact Software Support for assistance.

EEWN0120E

An internal error "exception" has occurred. The error message is: "exception_message".

Explanation

See message.

System action

The IBM Workload Scheduler job is put into the "abend" status.

Operator response

Resubmit the PeopleSoft process. If the problem persists, contact Software Support for assistance.