5621-IAJ - Documentation Index
Table of Contents
Welcome
Start Here
What's new
Overview
TS7785 product introduction
TS7785 system configurations
Hardware overview
TS7785 Hardware overview
TS7785 product structure
TS7785 product structure
TS7785 Server (4986-VEL)
TS7785 Cache Controller (4986-CFL)
TS7785 Cache Expansion (4986-XSL)
TS7785 Disk subsystem concepts
TS7785 Disk subsystem concepts
Cache 4986-CFL/XSL overview
4986-CFL/XSL frame layout
4986-CFL/XSL array
4986-CFL/XSL Serviceability or Repair process
TS7785 Cache (CFL/XSL) Storage Management GUI
Disk subsystem storage hierarchy
Logical unit mapping
Host and drive channel relationships
General Parallel File System
Feature details
TS7785 Feature details
Capacity on Demand
TS7785 capacity on demand
Installing, removing, replacing TS7785 components
Installing microcode and software
Verifying the microcode level
Clearing Images from the Installation Directory
Installing TS7785 microcode images
Creating or updating backup media
Removing and replacing TS7785 components
Removing and replacing F01 tape frame components
Removing and replacing a power distribution unit (PDU)
Removing and replacing an Ethernet switch (4986-VEL)
Removing and replacing the TS7785 server components
Removing and Replacing Server 4986-VEL components
Hot-swapping the Ethernet Adapter Card (Copper/Fiber)
Hot-swapping the VEL FC Adapter Card (Fiber channel)
Hot-swapping the Host adapters
Cables
Control panel cables for 4986-VEL
Removing and replacing the control panel cable in the 4986-VEL
Preparing the 4986-VEL system to remove and replace the control panel cable
Removing the control panel cable from the 4986-VEL system
Replacing the control panel cable in the 4986-VEL system
Preparing the 4986-VEL system for operation after removing and replacing the control panel cable
Removing and replacing the control panel display cable in the 4986-VEL Server
Preparing the 4986-VEL system to remove and replace the control panel display cable
Removing the control panel display cable from the 4986-VEL system
Replacing the control panel display cable in the 4986-VEL System
Preparing the 4986-VEL system for operation after removing and replacing the control panel display cable
Drive backplane cables in 4986-VEL
Removing and replacing the drive backplane power cable in the 4986-VEL
Preparing the 4986-VEL system to remove and replace a drive backplane power cable
Removing the drive backplane power cable from the 4986-VEL system
Replacing the drive backplane power cable in the 4986-VEL system
Preparing the 4986-VEL system for operation after removing and replacing a drive backplane power cable
Removing and replacing the drive backplane signal cable in the 4986-VEL
Preparing the 4986-VEL system to remove and replace a drive backplane signal cable
Removing the drive backplane signal cable from the 4986-VEL system
Replacing the drive backplane signal cable in the 4986-VEL system
Prepare the 4986-VEL system for operation after removing and replacing a drive backplane signal cable
Fan cables for 4986-VEL
Removing and replacing a fan cable
Preparing the 4986-VEL system to remove and replace a fan cable
Removing the fan cable from the 4986-VEL system
Replacing the fan cable in the 4986-VEL system
Preparing the 4986-VEL system for operation after removing and replacing a fan cable
Front drive cable for 4986-VEL
Removing and replacing the front drive cable in 4986-VEL
Preparing the 4986-VEL system to remove and replace the front drive cable
Removing the front drive cable from the 4986-VEL system
Replacing the front drive cable in the 4986-VEL system
Preparing the 4986-VEL system for operation after removing and replacing the front drive cable
Front USB cable for 4986-VEL
Removing and replacing the front USB cable in 4986-VEL
Preparing the 4986-VEL system to remove and replace the front USB cable
Removing the front USB cable from the 4986-VEL system
Replacing the front USB cable in the 4986-VEL system
Preparing the 4986-VEL system for operation after removing and replacing the front USB cable
Power signal cable for 4986-VEL
Removing and replacing the power signal cable in 4986-VEL
Preparing the system to remove and replace the power signal cable in 4986-VEL
Removing the power signal cable from 4986-VEL
Replacing the power signal cable in 4986-VEL
Preparing the system for operation after removing and replacing the power signal cable in 4986-VEL
Rear SAS cable for 4986-VEL
Removing and replacing the rear SAS cable in 4986-VEL
Preparing the 4986-VEL system to remove and replace the rear SAS cable
Removing the rear SAS cable from the 4986-VEL system
Replacing the rear SAS cable in the 4986-VEL system
Preparing the 4986-VEL system for operation after removing and replacing the rear SAS cable
Rear USB cable for 4986-VEL
Removing and replacing the rear USB cable in 4986-VEL
Preparing the 4986-VEL system to remove and replace the rear USB cable
Removing the rear USB cable from the 4986-VEL system
Replacing the rear USB cable in the 4986-VEL system
Preparing 4986-VEL system for operation after removing and replacing the rear USB cable
Control panel and control panel display for the 4986-VEL
Removing and replacing the control panel in 4986-VEL
Preparing the 4986-VEL system to remove and replace the control panel
Removing the control panel from the 4986-VEL system
Replacing the control panel in the 4986-VEL system
Preparing the 4986-VEL system for operation after removing and replacing the control panel
Removing and replacing the control panel display in 4986-VEL
Preparing the 4986-VEL system to remove and replace the control panel display
Removing the control panel display from the 4986-VEL system
Replacing the control panel display in the 4986-VEL system
Preparing the 4986-VEL system for operation after removing and replacing the control panel display
Drive backplanes for 4986-VEL
Remove and replace the drive backplane of a 4986-VEL
Prepare the 4986-VEL system to remove and replace the base function disk drive backplane
Removing the base function disk drive backplane from the 4986-VEL system
Replacing the base function disk drive backplane in the 4986-VEL system
Preparing the 4986-VEL system for operation after removing and replacing the base function disk drive backplane
Removing and replacing the 12-drive expanded function disk drive backplane in 4986-VEL
Preparing the 4986-VEL system to remove and replace the 12-drive expanded function disk drive backplane
Removing the 12-drive expanded function disk drive backplane from the 4986-VEL system
Replacing the 12-drive expanded function disk drive backplane in the 4986-VEL system
Preparing the 4986-VEL system for operation after removing and replacing the 12-drive expanded function disk drive backplane
Removing and replacing the 18-drive expanded function disk drive backplane in the 4986-VEL
Preparing the 4986-VEL system to remove and replace the 18-drive expanded function disk drive backplane
Removing the 18-drive expanded function disk drive backplane from the 4986-VEL system
Replacing the 18-drive expanded function disk drive backplane in the 4986-VEL system
Preparing the 4986-VEL system for operation after removing and replacing the 18-drive expanded function disk drive backplane
Removing and replacing the NVMe drive backplane in 4986-VEL
Preparing the 4986-VEL system to remove and replace the NVMe drive backplane
Removing the NVMe drive backplane from the 4986-VEL system
Replacing the NVMe drive backplane in the 4986-VEL system
Preparing the 4986-VEL system for operation after removing and replacing the NVMe drive backplane
Removing and Replacing the NVMe drive ( Concurrently )
Removing and Replacing a fan in the 4986-VEL
Remove and Replace memory modules for the 4986-VEL
Preparing the system
Removing a memory module
Replacing a memory module
Preparing the system for operation
Plugging rules for memory modules
NVMe U.2 pass-thru cards for the 4986-VEL
Preparing the system
Removing an NVMe U.2 pass-thru card
Replacing an NVMe U.2 pass-thru card
Preparing the system for operation
Removing and replacing a PCIe3 x8 SAS RAID adapter
Preparing the system
Removing a PCIe3 x8 SAS RAID or cache SAS RAID internal adapter
Replacing a PCIe3 x8 SAS RAID or cache SAS RAID internal adapter
Preparing the system for operation
Remove and Replace power supplies in the 4986-VEL
Preparing the system
Removing a power supply
Replacing a power supply
Preparing the system for operation
Removing and Replacing a service processor card for the 4986-VEL
Preparing the system
Removing the service processor card
Replacing the service processor card
Preparing the system for operation
Remove and Replace a system processor module in the 4986-VEL
Preparing the system
Removing the system processor module
Replacing the system processor module
Preparing the system for operation
Remove and Replace time-of-day battery in the 4986-VEL
Preparing the system
Removing the time-of-day battery
Replacing the time-of-day battery
Preparing the system for operation
Remove and Replacing a trusted platform module card in the 4986-VEL
Preparing the system
Removing the trusted platform module card
Replacing the trusted platform module card
Preparing the system for operation
Common procedures for the 4986-VEL
Before you begin
Identifying a part
Identifying the enclosure or server that contains the part to be replaced
Enabling enclosure or server indicators by using the ASMI
Control panel LEDs
Finding the part location code and LED support status
Identifying a part by using the ASMI
Activating the identify LED by using the ASMI when you know the location code
Activating the identify LED by using the ASMI when you do not know the location code
Identifying a part by using the TS7785 rasMenu menus
Starting a system
Control Panel LEDs
Removing and installing system covers on the 4986-VEL
Removing and installing the front cover on the 4986-VEL
Removing and installing the service access cover on the 4986-VEL
Removing and replacing the air baffle on the 4986-VEL
Service and operating positions for the 4986-VEL
Placing the 4986-VEL into the service position
Placing the 4986-VEL into the operating position
Power cords
Disconnecting the power cords from the 4986-VEL System
Connecting the power cords to the 4986-VEL system
Deactivating an identify LED
Deactivating a system attention LED by using the operating system or VIOS tools
Deactivating the indicator light for a part by using AIX® diagnostics
Deactivating the indicator light by using the IBM i operating system
Deactivating the indicator light by using the Linux operating system
Deactivating the indicator light for a part by using the VIOS tools
Deactivating a system attention LED by using the ASMI
Deactivating the identify LED by using the ASMI when you know the location code
Deactivating the identify LED by using the ASMI when you do not know the location code
Deactivating a check log indicator (system information indicator) by using the ASMI
Deactivating LEDs by using the HMC
Deactivating a system attention LED or partition LED by using the HMC
Deactivating an identify LED for a FRU by using the HMC
Deactivating an identify LED for an enclosure by using the HMC
Removing and replacing TS7785 cache components
Replacing 4986-CFL/XSL components
Procedure: Identifying which enclosure or canister to service
Procedure: Powering off the system
Procedure: Powering off a node canister
Removing and replacing a CFL power supply unit
Removing and replacing a drive
Removing and replacing a CFL drive slot filler
Removing and replacing an CFL enclosure fan
Removing and replacing a canister
Removing and replacing an interface adapter
Removing and replacing the CFL canister fans
Removing and replacing a CFL memory module
Removing and replacing the CFL canister battery
Removing and replacing the CFL canister CMOS battery
Removing and replacing a TPM
Removing and replacing an SFP transceiver
Removing and replacing a faulty CFL node canister
Removing and replacing the CFL midplanes (IBM SSR procedure)
Removing and replacing the 2U enclosure end caps
Removing and replacing the enclosure bezel
Replacing the XSL expansion enclosure support rails
Replacing an XSL expansion enclosure midplane assembly
Replacing a power supply unit for an expansion enclosure
Replacing a 4986-XSL expansion canister
Replacing SAS Cables for CFL/XSL enclosure
Removing and replacing TS7785 cables
TS7785 cabling (4986-VEL/CFL/XSL)
Removing and replacing cables
Base frame power cable diagrams for the 4986-VEL server attached to 4986-CFL/XSL
Base frame Ethernet cable diagrams for the 4986-VEL server attached to 4986-CFL/XSL
Base frame Fiber cable diagrams for the 4986-VEL server attached to 4986-CFL/XSL
SAS cable diagrams for the TS7785 cache
Replaceable units
Control enclosure replaceable units
2U expansion enclosure replaceable units
High density expansion enclosure replaceable units
Installing and starting the TS7785 Service Documentation
Before you begin
Storage Acclimation
Avoiding electric shock
Handling static-sensitive devices
List of concurrent replacement parts
List of non-concurrent replacement parts
Establishing a service connection to the TS7785
Configuring a PuTTY Serial Connection
Connecting from the TSSC to the TS7785 using Secure Shell (SSH)
Logging in to the TSSC
Non-authenticated login to the TSSC
Authenticated login to the TSSC
Authenticating and logging in to the TS7785 (local)
Connecting to a TS7785 using a serial connection
Connecting to the TS7785 from TSSC
Connecting to the TS7785 from a notebook
TS7785 menu
Security controls
Security for local access
Security for remote support access
Preparing for service
TS7785 Grid service preparation menus
Displaying current Grid service / service prep status
Displaying the service task tracking status
Displaying current mounted devices within the Grid
Initiating service prep
Initiating a forced service prep
Canceling service prep
Stopping a TS7785
Preparing for service (Grid environment)
Varying an entire Grid offline
Varying a cluster offline (Grid environment)
Forcing the TS7785 offline
Varying a TS7785 offline (non-Grid environment)
Control Unit Initiated Reconfiguration (CUIR)
Shutting down and restarting the TS7785
Shutting down the TS7785
Restarting the TS7785
Shutting down the Cache Cxx and Server Vxx
Shutting down the TS7785 frame
Verify the repair to the system
System Checkout Functions
System checkout
Refresh/Rerun Specific system checks
Disable specific system checks temporarily
Display temporarily disabled specific system checks
Resetting the TS7785-Cache disk system checkout degradation message
End-of-Call procedure
Starting a TS7785 Virtualization Engine
Powering on a TS7785 system
Displaying online or offline status of the TS7785
Varying a TS7785 online (non-grid environment)
Varying a TS7785 online (grid environment)
Displaying current events preventing online capability
Adding or removing user controlled event for online capability
Clear ALL online events preventing online capability
Configuring
Configuring system interfaces
Creating a serial connection on the TSSC
Opening and enabling a serial connection on the TSSC
Logging out of the TSSC
Configuring a PuTTY Serial Connection
Connecting NetTerm directly through a T1 port
Configuring Assist On-Site (AOS)
IBM TSSC Maintenance information
Showing or changing the Vital Product Data (VPD)
Configuring the physical components
Configuring the Fibre Channel switches
Configuring the network
Configuring customer network after initial installation
Changing the TSSC TCP/IP configuration of the TS7785 using rasMenu
Changing the TCP/IP configuration of the customer network using TS7785
Updating VPD from current customer network setting
Changing the console settings on the TSSC
Adding attached system information
Changing the subsystem settings on the TS7785
Setting the date and time
Setting the Network Time Protocol server address for date/time synchronization
Setting the date and time on the 4986-VEL
Removing Network Time Protocol server IP address
Configuring call home and remote services
Configuring the TSSC IP settings
Changing/showing call home/remote services
Configuring the send test notification menu
Configuring remote data monitoring
Reenabling Call Home through the TS7785 menu
Configuring TS7785 functions
Setting the data consistency point
Grid configuration (join)
Reconfigure TS7785 GRID network IPs
Maintaining
Maintaining the TS7785 Cache
Disk Cache Dynamic Rebuild
Recovering the IBM TS7785
Recovering the TS7785 Cache Controller
Repairing fibre paths after recovering the TS7785 cache controller
Backout Failed Cache MES
Working with disk cache encryption
Showing disk cache encryption settings
Regenerating Emergency Recovery Keys
Troubleshooting and Support
Starting point for troubleshooting the Enterprise controller TS7785
How to find hot tokens in the grid?
Do you already have an error code, message, service request number, or system reference code?
Working with a Call Home record
Are you here because of system cache problems?
Do you want to RUN a system checkout?
Do you want to DISPLAY System Checkout status?
Do you need to review the service information messages log?
Working with service information messages in the SIM Log
Viewing service information messages (SIMs)
Service and media information messages
Decoding service information messages (SIMs) reference codes
Showing or changing the service information message and media information message reporting level
Closing service information messages (SIMs)
ES/9000® environmental recording, editing and printing (EREP) reports
Service information messages environmental recording, editing and printing report (Format 71)
Do you need to review the subsystem error log?
Subsystem error log review
Do you need to perform a visual verification of the machine?
Messages and codes (TS7785)
Messages, codes, and service request numbers entry table
Service request numbers (SRNs)
Using service request numbers
Using the list of service request numbers
Service request number source code
Service request numbers 000-xxx through 5Fx-xxx
PFW1540
MAP0050 SCSI bus problems
Service request numbers 60B-xxx through 69d-xxx
Service request numbers 700-xxx through 799-xxx
Service request numbers 801-xxx(x) through 891-xxx(x)
Service request numbers 900-xxx through 9CC-xxx
Service request numbers A00-FF0 through A25-001
Service request numbers 1000-xxxx through 1xxx-xxxx
Service request numbers 2520-xxx through 25F8-xxx
Service request numbers 2600-101 through 2685-xxx
Service request numbers 8083-xxxx through 8125-xxxx
Small computer system interconnect devices' service request numbers (ssss-102 to ssss-640)
General small computer system interconnect configuration checks
Service request numbers E0–xxxx fibre connection codes
Failing function codes, failing items, and symbolic FRUs
Failing function codes
Symbolic FRUs
Failing items
Messages and codes
Messages, codes and service request numbers entry table
System reference codes and firmware codes
Using the list of system reference codes and firmware codes
List of system reference codes and firmware codes
(1000xxxx - 1100xxxx - 1xxxxxxx) System power control network reference codes
Removing and replacing a 3957-V07/VEB Quad port 1 Gb Ethernet card
Removing and replacing a 3957-V07/VEB Base RAID card
Removing and replacing a system backplane in a 3957-V07/VEB
Removing and replacing a 4986-VEL system unit disk drive
(5xxxxxxx) Reference codes
(573Axxxx) Reference codes
(573Bxxxx) Reference codes
(573Cxxxx) Reference codes
(576Axxxx) Reference codes
(5708xxxx) Reference codes
(574Fxxxx) Reference codes
(A1xxxxxx) Service processor reference (attention) codes
(A7xxxxxx) Licensed Internal Code (LIC) reference codes
(AAxxxxxx) Partition firmware reference (attention) codes
(B1xx) Service processor firmware reference codes
(B1xxxxxx) Service processor firmware reference codes
(B15172xx or B18172xx) Service processor early termination reference codes
(B2xxxxxx) Logical partitioning reference codes
B7 xxxxxx Licensed internal code (LIC) reference codes
(BAxxxxxx) Partition firmware reference (attention) codes
(DAxxxxxx) Partition firmware reference (error) codes
Service request numbers (SRNs)
Using service request numbers
Using the list of service request numbers
Service request number source code
Service request numbers 000-xxx through 5Fx-xxx
Service request numbers 60B-xxx through 69d-xxx
Service request numbers 700-xxx through 799-xxx
Service request numbers 801-xxx(x) through 891-xxx(x)
Service request numbers 900-xxx through 9CC-xxx
Service request numbers A00-FF0 through A25-001
Service request numbers 1000-xxxx through 1xxx-xxxx
Service request numbers 2520-xxx through 25F8-xxx
Service request numbers 2600-101 through 2685-xxx
Service request numbers 8083-xxxx through 8125-xxxx
Small computer system interconnect devices' service request numbers (ssss-102 to ssss-640)
General small computer system interconnect configuration checks
Service request numbers E0–xxxx fibre connection codes
Failing function code list
Map part number to custom card identification number or failing function code
Unused failing function codes
Miscellaneous Operator panel codes
Progress codes
Using progress codes
List of progress codes
Advanced Interactive Executive initial program load progress codes
IPL progress codes for the 4986-VEL
Advanced Interactive Executive diagnostics load-progress codes
Dump progress indicators (Dump status codes)
Crash codes
Service processor progress codes
(C1xxxxxx) Service processor progress codes (checkpoints)
(C2xxxxxx) Virtual service processor progress codes
Initial program load status progress codes (C3yx, C500, C600, C6xx)
(C700xxxx) Server firmware initial program load status progress codes
(C900xxxx) Initial program load status progress codes
(CAxxxxxx) Partition firmware progress codes
(Dxxx) System firmware progress codes
(D100xxxx) Service processor progress codes (service processor dump and platform dump)
(D1xxxxxx) Service processor status progress codes
(D200xxxx) Partition status progress codes
(D6xxxxxx) General status progress codes
(D9xxxxxx) General status progress codes
(Exxx) System firmware progress codes
Microcode detected errors
Showing a microcode detected error (MDE)
TS7785 MDE codes
Primary FC switch issues
Alternate FC switch issues
Both FC switch issues
Removing and replacing an SMC (Ethernet) switch in a TS7785
Ethernet switch failure
Library manager (LM) Call Home error codes
AIX DDM and RDAC Errors
Storage Manager errors - Recovery Guru - resolutions
Explanation of INTERFACE ID value from DISPLAY M=DEV command
Alternative tools for service support, and troubleshooting
Open Firmware Prompt
Using System Management Services (SMS)
Managing the Advanced System Management Interface (ASMI)
ASMI Overview
Advanced System Management Interface concepts
Advanced System Management Interface requirements
Managing your server using the Advanced System Management Interface
ASMI Setting the IP address on a PC, notebook, or TSSC
Setting the IP address to access the ASMI (Supported in 4986-VEL server)
Setting the ASMI IP address on the TSSC
ASMI Access
Accessing the Server VEC/VED ASMI using a PC or notebook and web browser
Accessing the ASMI by using an ASCII console
ASMI Tasks
Viewing vital product data
Setting expansion unit configuration ID and MTMS value
Using the ASMI to perform a system dump
Using the ASMI to perform a service processor dump
Setting the system enclosure type
Setting the system identifiers
Using the ASMI to switch to the other side of the service processor
Testing and diagnostics
Running diagnostic functions
Running the online or stand-alone diagnostics
Running the online diagnostics
Running the online diagnostics in service mode
Running the online diagnostics in maintenance mode
Running the online diagnostics in concurrent mode
Resetting the service processor
Problem indicators
Notification overview
Attention lights overview
Messages overview
Reference codes overview
Subsystem error log review
Display current Grid link statistics (gridadmin link show)
Perform Wide Area Network (WAN) Test
Performing a ping test against a configured system address
Isolation MAPs and symbolic field replaceable unit (FRU) procedures for the Server 4986-VEL
A procedures
ACMODUL
AIRMOVR
AJDG301
Ambient temperature (AMBTEMP)
ANYBRDG
ANYPROC
B procedures
BACKPLN
BATRY
BRDGSET
C procedures
CABLEH
CAPACTY
CBLALL
CBLCONT
CLCKMOD
CTLPNL
D procedures
DEVBPLN
F procedures
FSPSP01
FSPSP02
FSPSP03
FSPSP04
FSPSP05
FSPSP06
FSPSP07
FSPSP08
FSPSP09
FSPSP10
FSPSP11
FSPSP12
FSPSP16
FSPSP17
FSPSP18
FSPSP20
FSPSP21
FSPSP22
FSPSP23
FSPSP24
FSPSP25
FSPSP26
FSPSP27
FSPSP28
FSPSP29
FSPSP30
FSPSP31
FSPSP32
FSPSP34
FSPSP35
FSPSP36
FSPSP37
FSPSP38
FSPSP39
FSPSP40
FSPSP46
FSPSPC1
FSPSPD1
FWADIPL
FWCD2
FWENET
FWFLASH
FWFWPBL
FWHOST
FWIDE1
FWIDE2
FWIPIPL
FWLPAR
FWMBOOT
FWNIM
FWNVR1
FWNVR2
FWPCI1
FWPCI2
FWPCI3
FWPCI4
FWPCI5
FWPTR
FWSCSI1
FWSCSI2
FWSCSI3
FWSCSI4
FWSCSI5
FWSCSIH
H procedures
HSL2
HSL2_03
HSL2_10
HSL2_xx
HSL_LNK
I procedures
I2CBUS
IDPART
IO_HUB
IOBRDG
L procedures
LICCODE
M procedures and MAPs
MA_BRDG
MABIP50
MAILBOX
MAP0xxx range
MAP0020 Problem determination procedure
MAP0023 failure reading DVD-RAM disc
MAP0024 failure reading DVD-RAM disc
MAP0050 SCSI bus problems
MAP0054 PCI-X SCSI bus problems
MAP0058-100 Fibre switch problems
MAP0260 System hangs during resource configuration
MAP0270 small computer system interconnect RAID problem resolution and verification
MAP0280 Console and Keyboard Problem Resolution
MAP0290 Missing Resource Problem Resolution
MAP0291 Missing device or bus problem resolution
MAP0210 General problem resolution
MAP1xxx range
MAP1110 SIM generation and interpretation for z/OS
MAP1130 primary power supply Fan Normal and Failure Modes
MAP1200 Prioritizing serviceable events and visual symptoms for repair
MAP1210 Displaying and repairing a serviceable event
MAP1320 Isolating problems using visual symptoms
MAP2xxx range
MAP2030 Check/Reorder Cable field replaceable unit
MAP2031 Repair ground continuity
MAP2040 Check primary power supply input circuit breaker
MAP2050 Loss of alternate current (AC) Input to a single primary power supply (PPS)
MAP20D0 Primary power supply (PPS) input phase missing
MAP2130 Isolating power symptoms
MAP2160 Power system identify light-emitting diode (LED) failure
MAP2210 Power failure not isolated
MAP2350 Ethernet switch power problem
MAP4xxx range
MAP4060 Restoring vital product data card settings
MAP4065 Restoring Service Processor card settings
MAP4070 central processor complex (CPC) memory problem
MAP4100 Repairing a service processor card (FSP) problem
MAP4360 Codes displayed by the central processor complex (CPC) enclosure control panel
MAP4370 central processor complex enclosure control panel does not show a normal display
MAP4560 No valid subsystem status available
MAP4810 Resetting the service processor card (FSP)
MAP4820 Performing a slow boot of a processor complex
MAP4840 4986-VEL failing to power off during service processor card repair
MAP4E00 RAID input/output (RIO)/system power control network (SPCN) problems
MAP5xxx range
MAP5300 fibre channel link fault
MAP5305 fibre channel bit error rate test failure
MAP5321 Fibre channel optical power measurement
MAP5340 count key data (CKD) read data failure
MAP5410 Fibre channel bit error validation
MAP5440 Fiber host card reports a loss of light
MASBUS
MEDIA
MEMBRD
MEMCTLR
MEMDIMM
N procedures
NEXTLVL
NO_PNUM
NODEPL
O procedures
OPT_CLN
P procedures
PFW1540
PFW1542
PFW1548
PGDPART
PIOCARD
PPCIMIN
PPCISYS
PPCITWR
PRI_PCI
PWR1900
PWR1904
PWR1909
PWR1911
PWR1916
PWR1917
PWR1918
PWRCBL
PWROC
PWRSPLY
Q procedures
QDCCRLS
R procedures
RIOIP01
RIOIP02
RIOIP03
RIOIP04
RIOIP06
RIOIP07
RIOIP08
RIOIP09
RIOIP10
RIOIP11
RIOIP12
RIOIP50
RIOIP55
S procedures
SI_CARD
SI_PHB
SIADPCD
SICNTRL
SIRGCFG
SIIOADP
SIRSTAT
SLOTERR
SPBUS
SRCTB1X
SVCDOCS
SVCPROC
SYSBKPL
T procedures
TOD_BAT
TOPORT
TWRCARD
TWRPLNR
U procedures
USBPGD
V procedures
VPDPART
Logs, dumps, and traces
Generating an Error Report using a Sequence Number
Viewing service logs
Gathering multiple system logs
Log File Collection
Collect Logs Relative to the Current Date/Time
Collect Logs for a Specific Date/Time
Collect Logs for a Specific Date/Time Range
Managing dumps
Performing dumps
Performing a platform system dump
Performing a system dump by using the control panel
Performing a system dump by using the Advanced System Management Interface
Performing a service processor dump
Performing a service processor dump by using the control panel
Performing a service processor dump by using the Advanced System Management Interface
Sending problem determination files
Sending the problem determination files home through call home modem
Verifying the log files in call home record
Sending the problem determination files to a universal serial bus key or blank CD-ROM
Troubleshooting tape frame components (fibre switches and drive configuration)
Tape path problem determination for 8 Gb and 4 Gb Fibre Channel switches
Failed tape path recovery for 8 GB and 4 GB fibre switches
16 Gb 48-Port Fibre Channel switch
Troubleshooting the 16 Gb 48-Port Fibre Channel switch LEDs
16 Gb 48-Port Fibre Channel switch setup
32 Gb 48-Port Fibre Channel switch
Troubleshooting the 32 Gb 48-Port Fibre Channel switch LEDs
32 Gb 48-Port Fibre Channel switch setup
Troubleshooting the TS7785 cache
Troubleshooting the 4986-CFL/XSL cache
Accessing the Storage Management GUI
Canceling the Cache CFL firmware update
Accessing the Storage Management GUI using the TSSC
Accessing the Storage Management GUI using the TSSC browser
Accessing the Storage Management GUI directly from the Cache CFL controller
Collecting the Cache CFL Snap/logs from Storage Management GUI
Getting configuration information from Cache CFL using a USB
Troubleshooting a Server Vxx that will not boot up
Troubleshooting Hints and Tips
Reference, parts and diagrams
Parts listings, assembly, and cabling diagrams
Finding part locations
Understanding location codes
Location codes for TS7785 Server (VEL)
TS7785 Server (VEL) parts
TS7785 Server VEL parts and part assembly diagram
TS7785 Cache (CFL and XSL) parts
4986-CFL Control enclosure replaceable units
4986-XSL expansion enclosure replaceable units
4986-F01 Frame parts and part assembly diagrams
TSSC parts
Part assembly diagrams
Hardware LED reference
10Gb Dual Port LW adapter (FC 1046)
49xx-Cxx Node canister indicators
Procedure: Understanding the system status LEDs
Host Interface Adapter ports and indicators
Glossary
Notices
Terms and conditions for information centers
Trademarks
Safety and Environmental notices
Safety Information
Power On - Inspect the customer power receptacles and connect power to the TS7785
IBM safety publication
Alternating current (AC) grounding inspection
Safety inspection procedures
Completion report
Materials Needed
Safety labels
Safety notices
Acoustic Notice
Environmental notices
Taiwan Hazardous Substance Table
ESD procedures
How to attach the ESD wrist strap
Electronic emission notices
United States Federal Communications Commission (FCC) Notice
Industry Canada compliance statement
European Union Electromagnetic Compatibility Directive
Australia and New Zealand Class A Statement
Germany Electromagnetic compatibility directive
People's Republic of China Class A Electronic Emission statement
Taiwan Class A compliance statement
Taiwan contact information
Japan Voluntary Control Council for Interference (VCCI) Class A Statement
Japan Electronics and Information Technology Industries Association Statement
Korean Communications Commission (KCC) Class A Statement
Russia Electromagnetic Interference (EMI) Class A Statement
Publications
IBM safety publication
Additional IBM® TS7785 publications
Printable PDF publications