TS7770 minimum configuration requirements

The following components are the minimum configuration requirements for a TS7770 with microcode level 8.53.0.x.

TS7770 minimum configuration requirements for TS7700 with CSB/XSB cache with microcode level 8.53.0.x:

One 3948-F0x Tape Frame with the following features:
  • FC 1912, Single Phase Power Distribution Unit (For F07)
  • FC 1913, Single Phase Power Distribution Unit (F07)
  • FC 2704, TSSC expansion 26-port Ethernet switch/rackmount
  • FC 2725, Rack Mount TSSC
  • FC 5512, KVM
  • FC 5631, Install 3948 VED
  • FC 5663, Plant install 3948-CSB
  • FC 5664, Plant Install 3948 XSB
  • FC 5756, Integrated control path
  • FC 7338, Encryption Capable Expansion Frame or FC 7339, TS7700 Encryption Capable Base Frame (F07)
  • FC 9906, New order install
  • FC AG00, Shipping and Handling
  • A power cord appropriate for the country of installation selected from:
One TS7770 Server (3948-VED) with the following features:
  • FC 9268, Plant installation of 100 MB/s throughput
  • FC 9000, Mainframe attachment
  • FC AG00, Shipping and Handling
  • FC 9350, Plant Install
  • Two grid adapters:
    • FC 1039, 1 Gb grid quad port copper connection
    • FC 1038, 10 Gb dual port optical LW connection

      Or

    • FC 1041, 10 Gb dual port optical LW connection
  • Either two of host to TS7700 FICON cables (FC 0201, 9-micron LC/LC 31-meter or FC 0203, 50-micron LC/LC 31-meter) or one FC 9700, No factory cables
  • Two FICON adapters:
    • Two of “FC 3402, 16 Gb SW FICON Adapter” on page 110
    • Two of “FC 3403, 16 Gb FICON Long Wavelength Attachment” on page 110
  • FC 8080 (HDDs) or FC 8081(SDDs)

FC 2715, Console attachment

FC 9277, External Disk Encryption Certificate - Plant

One TS7770 Cache Controller (3948-CSB) with the following features: