MT 3948-VEF and F08 Feature details
This topic describes feature codes for 3948 Machine Type (Expert Care).
FC 0201, 9 Micron LC/LC 31 Meter
This feature provides one 31 meter (101 ft.) 9 micron single mode fibre cable with LC Duplex connectors on both ends, for connection between the Long Wavelength FICON Channel feature and a host system or fibre component long wavelength channel with a 9 micron fibre cable LC Duplex adapter.
Refer to TS7780 Feature Details in for requirements and other information.
FC 0203, 50-micron LC/LC 31-meter
This feature provides one 31 meter (101 ft.) 50 micron multimode fibre cable with LC Duplex connectors on both ends, for connection between the Short Wavelength FICON Channel feature and a host system or fibre component short wavelength channel with a 50 micron fibre cable LC Duplex adapter.
Refer to TS7780 Feature Details for requirements and other information.
FC 0983, TAA Compliance
This feature specifies the machine shipment is to comply with the U.S. Trade Agreements Act for USA orders only.
Refer to in 3948 TS7780 Features for requirements and other information.
FC 1034, Enable Second Port Grid Connection
This feature enables the second port of the dual port 1 Gb quad port 1Gb, or dual port 10 Gb Grid Connection adapters provided by #1042 and #1043.
Refer to in 3948 TS7780 Features for requirements and other information.
FC 1042, 1Gb Grid Quad Port Copper Connection
This feature provides a quad port 1-Gbps 10/100/1000Base-TX PCIe Ethernet adapter for Grid Communication between TS7780s with a single port enabled. This adapter has an RJ-45 connector for attaching Cat 6 cables. This adapter conforms to the IEEE 802.3ab 1000Base-T standard. It supports distances of up to 100 meters using four pairs of Cat 6 balanced copper cabling. Customer supplied Cat 6 cables must be used with the adapter when Grid Enablement (#4015) is installed.
Refer to in 3948 TS7780 Features for requirements and other information.
FC 1043, 10 GB Dual Port Grid Optical LW Connection
This feature provides a dual port 10-Gbps Ethernet longwave adapter for Grid Communication between TS7780s. This adapter has an LC Duplex connector for attaching 9 micron single mode fibre cable. It is a standard longwave (1,310 nm) adapter conforming to the IEEE 802.3ae standards. It supports distances up to 10 km.
Refer to in 3948 TS7780 Features for requirements and other information.
FC 1776, US RoHS Indicator
The state of Wisconsin requires RoHS compliant equipment. This feature will be selected as needed in the configurator for equipment that will be shipped to or used in Wisconsin.
Refer to in 3948 TS7780 Features for requirements and other information.
FC 1913, Single Phase Power Distribution Unit (F08)
This feature provides two 12 outlet PDUs to allow connection to independent branch power circuits. Replaces #1912. #1913 is also the foundation PDU for 3 phase power. Note that if 3 phase PDU is required you must also add iRPQ 8B3723 (3 phase PDU power cords).
Refer to FC 1913 (F08) in TS7780 Feature Details for requirements and other information.
FC 1913, Single Phase Power Distribution Unit
This feature provides two 12 outlet PDUs to allow connection to independent branch power circuits. Replaces #1912. #1913 is also the foundation PDU for 3 phase power. Note that if 3 phase PDU is required you must also add iRPQ 8B3723 (3 phase PDU power cords).
Refer to FC 1913 in TS7780 Feature Details for requirements and the information.
FC 2749, Lock and Key for 3948-F07, 3952-F07 and 3948-F08
This feature provides the lock and key for the 3948-F07, 3952-F07 and 3948-F08 base and expansion frames. 2749 supports just one frame, if ordering expansion frames you will need to add additional #2749 to match each frame.
Refer to FC 2749 in TS7780 Feature Details for requirements and other information.
FC 2750, Top Exit Cabling
This feature provides the re-routing of the cabling through the top of the 3948-F07, 3952-F07 and or 3948-F08 base and expansion frames. #2750 supports just one frame, if ordering expansion frames you will need to add additional #2750 to match each frame.
Refer to FC 2750 in TS7780 Feature Details for requirements and other information.
FC 3401, Enable FICON second port
Enable second port on each FICON adapter installed. Note: Unless No Factory Cables (#9700) has been selected, two cables are required for each active FICON port. When installing #3404, include two #0201 cables for each #3404 FICON card configured or and two #0203 for each #3405 FICON card configured.
Refer to in TS7780 Feature Details for requirements and other information.
FC 3404, 32 Gb SW FICON Adapter
This feature provides one short-wavelength FICON adapter with an LC Duplex connector. One port is active by default. The adapter attaches to a FICON host system short wave channel utilizing a 50 micron multimode fibre cable. Each FICON attachment can support up to 512 logical channels.
Refer to in 3948 TS7780 Features for requirements and other information.
FC 3405, 32 Gb LW FICON Adapter
This feature provides one long-wavelength FICON adapter, with an LC Duplex connector. One port is active by default. The adapter attaches to a FICON host system long wave channel utilizing a 9-micron single-mode fibre cable. The total cable length cannot exceed 10km. Each FICON attachment can support up to 512 logical channels.
Refer to in 3948 TS7780 Features for requirements and other information.
FC 3480, Additional 64GB memory for VEF
This feature provides an additional 64GB of memory (2 x 32GB DIMMS) that must be used in Pairs, bringing the total VEF memory to a maximum of 512GB.
Refer to in 3948 TS7780 Features for requirements and other information.
FC 4015, Grid Enablement
This feature delivers a key to enable the communication function that allows communication with other TS7700s in a Grid configuration. A path to each TS7700 must be enabled on one of the GNodes. Each TS7700 in a Grid must enable communication with the other TS7700s in the configuration.
Refer to in 3948 TS7780 Features for requirements and other information.
FC 4016, Remove Cluster from Grid
This feature delivers instructions for a one-time process to remove a cluster from a Grid. This is required before a Cluster Cleanup can be performed on any cluster which is configured to participate in a Grid. If this cluster is returned to service after the cleanup is performed, and it joins a Grid, another instance of #4016 is required if the cluster will be removed from the new Grid.
Refer to in 3948 TS7780 Features for requirements and other information.
FC 4017, Cluster Cleanup
This feature facilitates a onetime Cluster Cleanup, to clean the database, delete logical volumes from the Tape Volume Cache, and removing configuration data for host connections from a TS7780 cluster. Before the cleanup can occur, a cluster with #4015, Grid Enable, must be removed from the Grid using #4016. If another cleanup is required on this cluster, another instance of #4017 is required.
Refer to 3948 TS7780 Features for requirements and other information.
FC 4643 , Rack Mount Kit Virtualization engine with common controller
The Rack Mount kit delivers the mounting hardware, required to install the TS7780 Server in a customer provided 19" rack.
Refer to 3948 TS7780 Features for requirements and other information.
FC 4647, Rack Mount Kit Common Controller
The Rack Mount kit delivers the mounting hardware and cables required to in-stall the TS7780 Common Controller in a customer provided 19" rack along with a rack mounted TS7780 Server.
Refer to 3948 TS7780 Features for requirements and other information.
FC 4648, Rack Mount Kit XSD
The Rack Mount kit delivers the mounting hardware, required to install the TS7780 Server in a customer provided 19" rack.
Refer to 3948 TS7780 Features for requirements and other information.
FC 4649, Rack Mount Kit VEF with CFD
The Rack Mount kit delivers the mounting hardware and cables required to install the TS7780 HDD Cache Expansion drawer in a customer provided 19" rack along with a rack mounted TS7780 Server.
Refer to 3948 TS7780 Features for requirements and other information.
FC 4650, Rack Mount Kit for common controller
The Rack Mount kit delivers the mounting hardware and cables required to install the TS7780 SSD Cache Controller in a customer provided 19" rack along with a rack mounted TS7780 Server.
Refer to in 3948 TS7780 Features for requirements and other information.
FC 4651, Rack Mount Kit expansion cache drawer for SSDs
The Rack Mount kit delivers the mounting hardware and cables required to install the TS7780 SSD based Expansion Controller in a customer provided 19" rack along with a rack mounted TS7780 Server.
Refer to in 3948 TS7780 Features for requirements and other information.
FC 4694 , Initial Order XSD Customer Rack
This feature allows the initial order of a TS7780 HDD Expansion Cache Module into a customer installed Rack. This feature must be ordered on the 3948 VEF and the Rack Install feature #4648 must appear on the 3948 model XSD TS7780 Cache Module order.
Refer to 3948 TS7780 Features for requirements and other information.
FC 4698 , Initial Order XFD Customer Rack
This feature allows the initial order of a TS7780 Cache Module into a customer installed Rack. This feature must be ordered on the 3948 VEF and the Rack Install feature #4651 must appear on the 3948 model XFD TS7780 Cache Module order.
Refer to 3948 TS7780 Features for requirements and other information.
FC 4699 , Field Order XFD for Customer Rack
This feature allows the Field installation of up to 9 TS7780 Expansion Cache Module into a customer installed Rack. This feature must be ordered on the 3948 VEF and the Field Merge feature #9355 must appear on the 3948 model XFD TS7780 Cache Module order.
Refer to 3948 TS7780 Features for requirements and other information.
FC 4881, 32GB FC switch for Tape Library connectivity
This feature delivers two quad-ported 32 Gb Fibre Channel HBAs and associated cables. These HBAs connect to the TS7700 #7338 Expansion frame.
Refer to in 3948 TS7780 Features for requirements and other information.
FC 5244, Quad Port 32 Gb FC HBA
This feature indicates a TS7780 Server will be installed into the 3948 F08 Tape Frame. This feature must appear on the 3948 F08 Tape Frame order, and the Plant Install feature #9350 must appear on the TS7780 Server order.
Refer to FC 5244 in 3948 TS7780 Features for requirements and other information.
FC 5262, 20 TB cache enablement
This feature enables a 20 TB increment of disk cache to store user data.
Refer to FC 5262 in 3948 TS7780 Features for requirements and other information.
FC 5263, 100TB cache enablement
This feature enables a 100 TB increment of disk cache to store user data.
Refer to FC 5263 in 3948 TS7780 Features for requirements and other information.
FC 5268, 100 MB/sec Increment
This feature delivers a key to enable an additional 100 MB/sec increment of potential Peak Data Throughput. Enabling a data throughput increment does not guarantee that the overall VTS will perform at that data throughput level.
Refer to in 3948 TS7780 Features for requirements and other information.
FC 5270, Increased Logical Volumes. All 3948-VEF will come standard with a full complement of 4M logical volumes
All 4 million logical volumes will be included in each 3948-VEF as standard. Note: In a Grid configuration, feature #5270 must be installed on every cluster in the Grid to increase the number of supported logical volumes in that Grid. The number of logical volumes supported in a Grid is set by the cluster with the smallest number of feature #5270 increments installed.
Refer to in 3948 TS7780 Features for requirements and other information.
FC 5271, Selective Device Access Control
This feature authorizes the use of a set of Management Class policies that allow only certain logical control units or subsystem ids within a composite library to have exclusive access to one or more volumes. Note: In a Grid configuration, feature #5271 must be installed on every cluster in the Grid before any Selective Device Access Control policies can be defined in that Grid.
Refer to in 3948 TS7780 Features for requirements and other information.
FC 5272, Disk Enabled Encryption
This feature delivers the product license key required to enable disk-based encryption.
Refer to in 3948 TS7780 Features for requirements and other information.
FC 5273, TS7780 Tape Attach
Enable this TS7780 to be connected to a TS4500 Tape Library with TS1140/50/60 tape drives dedicated to the TS7780.
Refer to in 3948 TS7780 Features for requirements and other information.
FC 5274, TS7780 Tape Attach
Each instance of feature #5274 enables 1 TB of data in the active pre-migration queue for back-end tape or cloud data.
Refer to in 3948 TS7780 Features for requirements and other information.
FC 5275, Additional virtual devices
Each instance of feature 5275 enables up to 16 additional virtual devices (virtual tape drives).
Refer to in 3948 TS7780 Features for requirements and other information.
FC 5276, Disk Encrypt-External Key Manager
This feature delivers the product license key required to enable disk-based encryption using keys managed by an external key manager.
Refer to in 3948 TS7780 Features for requirements and other information.
FC 5278, Cloud Enablement
Enables transparent cloud tiering for cloud storage behind TS7780.
Refer to in 3948 TS7780 Features for requirements and other information.
FC 5279, 5 TB Active Premigration Queue
Each instance of feature #5279 enables 5 TB of data in the active pre-migration queue for back-end tape or cloud data.
Refer to in 3948 TS7780 Features for requirements and other information.
FC 5281, Secure Data Transfer
This feature enables Grid Encryption for data in flight.
Refer to in 3948 TS7780 Features for requirements and other information.
FC 5283, TS7780 Advanced Object Store for DS8000
This feature allows the TS7780 to store DFSMShsm object data from the DS8000.
Refer to in 3948 TS7780 Features for requirements and other information.
FC 5290, Tape tools – (default and mandatory)
Tape tools allow access to TS7700 tape tools and system reports.
Refer to in 3948 TS7780 Features for requirements and other information.
FC 5631, Install 3948 Virtualization engine
This feature indicates a TS7780 Server will be installed into the 3948 F08 Tape Frame. This feature must appear on the 3948 F08 Tape Frame order, and the Plant Install feature #9350 must appear on the TS7780 Server order.
Refer to FC 5631 in 3948 TS7780 Features for requirements and other information.
FC 5663, Plant Install 3948 Controller drawer
This feature allows the factory installation of a TS7780 common Controller CFD into a new 3948 F08 Tape Frame from the plant. This feature must appear on the 3948 F08 Tape Frame order, and the Plant Install a 3948 Controller feature #9352 must appear on the TS7780 Cache Controller Model CFD order.
Refer to FC 5663 in 3948 TS7780 Features for requirements and other information.
FC 5664, Plant Install 3948 Expansion cache drawer for HDDs
This feature allows the factory installation of a TS7780 Expansion Cache Module model XSD into a new 3948 F08 Tape Frame from the plant. This feature must appear on the 3948 F08 Tape Frame order, and the Plant Install a 3948 Expansion Cache Module feature #9354 must appear on the TS7780 Cache Module order.
Refer to FC 5664 in 3948 TS7780 Features for requirements and other information.
FC 5665, Field Install 3948 Expansion cache drawer for HDDs
This feature allows the field installation of a TS7780 Cache Expansion Module into a customer installed 3948 F08 Tape Frame. This feature must be ordered on the 3948 F08 Tape Frame and the Field Merge a 3948 Cache Module feature #9355 must appear on the TS7780 Cache Expansion Module order.
Refer to FC 5665 in 3948 TS7780 Features for requirements and other information.
FC 5666, Field Install 3948 CFD
This feature allows the field installation of a TS7780 Cache Controller Model CFD into a customer installed 3948 F08 Expansion Frame. This feature must be ordered on the 3948 F08 Tape Frame and the Field Merge a 3948 Cache Controller feature #9353 must appear on the TS7780 Cache Module order.
Refer to FC 5666 in 3948 TS7780 Features for requirements and other information.
FC 5668, Plant Install 3948 Expansion cache drawer for SSDs
This feature allows the factory installation of a TS7780 SSD Cache Expansion Module model XFD into a new 3948 F08 Tape Frame coming from the plant. This feature must appear on the 3948 F08 Tape Frame order, and the Plant Install a 3948 SSD flash Cache Expansion Module feature #9354 must appear on the TS7780 Cache Expansion Module order.
Refer to FC 5668 in 3948 TS7780 Features for requirements and other information.
FC 5669, Field Install 3948 for Expansion cache drawers for SSDs
This feature allows the field installation of a TS7780 SSD Cache Expansion Module into a customer installed 3948 F08 Tape Frame. This feature must be ordered on the 3948 F08 Tape Frame and the Field Merge a 3948 SSD flash Cache Expansion Module feature #9355 must appear on the TS7780 Cache Module order.
Refer to FC 5669 in 3948 TS7780 Features for requirements and other information.
FC 5757, Integrated Network Control Path
This feature provides the two Ethernet switches and cables to manage the network to the internal TS7780 drawer components.
Refer to FC 5757 in 3948 TS7780 Features for requirements and other information.
FC 5881, Plant Install 32GB FC switch for Tape Library connectivity
This feature indicates two 32GB Fibre Channel Switches will be plant installed into this 3948 Tape Frame. This feature must appear on the 3948 Tape Frame order, and the 32GB Switch feature #4881 must appear on the TS7700 3948-VEF Server order.
Refer to 3948 TS7780 Features for requirements and other information.
FC 5882, Field Install 32GB FC switch for Tape Library connectivity
This feature indicates two 32GB Fibre Channel Switches will be field installed into the 3948 Tape Frame. This feature must appear on the 3948 Tape Frame order, and the 32GB Switch feature #4881 must appear on the TS7700 3948-VEF Server order.
Refer to 3948 TS7780 Features for requirements and other information.
FC 5995, zTape Air-Gap with LTO
This feature provides a low-cost alternative customer rack mount solution to replace C06/C07 IBM controllers. #5995 offers z Mainframe customers a cost-effective solution using LTO8/09 tape drives within a TS4300 an air-gap tape drive for exporting tapes for backup and restore.
Refer to 3948 TS7780 Features for requirements and other information.
FC 7120, 240 TB SAS Storage
This feature specifies this device will be fully loaded with twelve 20 TB, 7,200 rpm, SAS HDDs providing 240 TB raw (156TB usable) disk storage capacity for 3948-XSD.
Refer to 3948 TS7780 Features for requirements and other information.
FC 7123, 360 TB SSD FLASH Expansion Storage
This feature specifies this device will be fully loaded with twenty-four, 15TB TB, SSD FLASH drives providing 360 TB raw (257TB usable) solid state disk storage capacity for 3948-XFD.
Refer to 3948 TS7780 Features for requirements and other information.
FC 7337, TS7780 HDD based Encryption Capable Base Frame
This feature designates the F08 Tape Frame for use as a TS7780 Encryption-Capable Base Frame.
Refer to 3948 TS7780 Features for requirements and other information.
FC 7338, TS7780 Encryption Capable Expansion Frame
This feature identifies this 3948 Tape Frame as the expansion frame for a TS7780 encryption-capable configuration. Only one #7338 expansion frames may be attached to the #7337 TS7780 Encryption Capable Base Frame. A second expansion frames is expected at a later date.
Refer to FC 7338 in 3948 TS7780 Features for requirements and other information.
FC 7339, TS7780 Encryption Capable SSD Base Frame (F08)
This feature designates the F08 Tape Frame for use as an SSD flash TS7780 encryption-capable frame. To be used when one 3948-CFD and up to ten 3948-XFD are used.
Refer to FC 7338 in 3948 TS7780 Features for requirements and other information.
FC 7405, Encryption CFD (USB Flash Drives (Four Pack))
Must be ordered on every 3948-CFD in the TS7780 configuration. Feature number 7405 will provide four USBs sticks per 3948-CFD used to store the local encryption keys. If external key management is later enabled, these USB sticks are no longer needed.
Refer to FC 7405 in 3948 TS7780 Features for requirements and other information.
FC 9000, Mainframe Attachment
This feature indicates attachment to System z, ES/3090, ES/9000, S/390 or zSeries hosts.
Refer to FC 9000 in 3948 TS7780 Features for requirements and other information.
FC 9219, Tape Library Attach
Refer to FC 9219 in 3948 TS7780 Features for requirements and other information.
FC 9268, 100 MB/s Throughput - Plant
This feature delivers a key to enable 100 MB/sec increment of potential peak data throughput. Enabling a data throughput increment does not guarantee that the overall Virtualization Engine will perform at that data throughput level. Installing the maximum number of feature #9268 plus #5268 removes any throughput limits.
Refer to FC 9268 in 3948 TS7780 Features for requirements and other information.
FC 9336, TS7780 1st Expansion Frame Attach
This feature identifies this TS7780 base frame 3948 Model F08 with #7337 has a first 3948 Model F08 with #7338 storage expansion frame attached to it.
Refer to FC 9336 in 3948 TS7780 Features for requirements and other information.
FC 9339, Replacing TS7700 Tape attach System
This feature instructs Manufacturing to ship the installation instructions to replace an existing TS7700 Tape attach system with this new TS7780 tape attach system.
Refer to FC 9339 in 3948 TS7780 Features for requirements and other information.
FC 9350, Plant Install
Refer to FC 9359 in 3948 TS7780 Features for requirements and other information.
FC 9352, Plant Install common controller drawer
This code specifies plant install of the common controller 3948-CFD into a new 3948 Tape Frame.
Refer to FC 9352 in 3948 TS7780 Features for requirements and other information.
FC 9354, Plant Install for expansion cache drawer for SSDs
This code specifies the factory installation of up to 10 SSD cache expansion drawers into a new 3948 F08 Frame coming from the plant.
Refer to FC 9354 (SSDs) in 3948 TS7780 Features for requirements and other information.
FC 9354, Plant Install for expansion cache drawer for HDDs
This code specifies the factory installation of an HDD cache expansion drawer into a new 3948 F08 Frame coming from the plant.
Refer to in FC 9354 (HDDs) in 3948 TS7780 Features for requirements and other information.
FC 9355, Field merge expansion cache drawer for SSDs
This code specifies the field merge of an SSD cache expansion drawer into a previously installed 3948 Tape Frame
Refer to FC 9355 (SSDs) in 3948 TS7780 Features for requirements and other information.
FC 9355, Field merge expansion cache drawer for HDDs
This code specifies the field merge of an HDD cache expansion drawer into a previously installed 3948 F08 Frame.
Refer to FC 9355 (HDDs) in 3948 TS7780 Features or requirements and other information.
FC 9700, No Factory Cables
This feature should be specified if you do not want the factory to ship any cable features with the new machine.
Refer to FC 9700 in 3948 TS7780 Features for requirements and other information.
FC 9900, Tape Encryption Config
This feature should be ordered when encryption will be used in a TS4500 Tape Library or TS7780 cluster. It includes publication updates with information on enabling and configuring the library (virtual or real) to support encryption. Customer initiated procedures need to be completed for enabling and configuring the TS4500 Tape Library or TS7780 cluster to support encryption with the TS1140/50/60 encryption capable tape drive.
Refer to FC 9900 in 3948 TS7780 Features for requirements and other information.
FC 9954, NEMA L6-30 Power Cord
This feature provides a NEMA L6-30 non-watertight 4.3 meter (14 foot) power cord, 200-208, 240 Vac, 24 Amps, used in U.S., Canada, Latin America, and Japan.
Refer to FC 9954 in 3948 TS7780 Features for requirements and other information.
FC 9955, RS 3750 DP Power Cord
This feature provides a Russell stoll 3750DP Watertight 4.3 meter (14 foot) power cord, 200-208, 240 Vac, 24 Amps, used in U.S, Chicago, Canada, LA, and Japan.
Refer to FC 9955 in 3948 TS7780 Features for requirements and other information.
FC 9956, IEC 309 Power Cord
This feature provides a IEC 309, p+n+g, 32A, 4.3 meter (14 foot) power cord, 230 Vac, 24 Amps, used in EMEA.
Refer to FC 9956 in 3948 TS7780 Features for requirements and other information.
FC 9957, PDL 4.3 Power Cord
This feature provides a PDL 4.3 meter (14 foot) power cord, 230-240 Vac, 23 Amps, used in Australia and New Zealand.
Refer to FC 9957 in 3948 TS7780 Features for requirements and other information.
FC 9958, Korean 4.3m Power Cord
This feature provides a NEMA L6-30 non-watertight 4.3 meter (14 foot) power cord, 200-208, 240 Vac, 24 Amps, with a Korean plug, used in North and South Korea.
Refer to FC 9958 in 3948 TS7780 Features for requirements and other information.
FC 9959, Unterminated Power Cord
This feature provides an unterminated, non-watertight 4.3 meter (14 foot), 200-208, 240 Vac, 24 Amps power cord with IRAM and BSMI agency certifications. This is the recommended cord for Argentina and Taiwan.
Refer to FC 9959 in 3948 TS7780 Features for requirements and other information.
FC 9966, China Unterminated Power Cord
This feature provides an unterminated, non-watertight 4.3 meter (14 foot), 200-208, 240 Vac, 24 Amps power cord with CCC agency certification. This is the recommended cord for China.
Refer to FC 9966 in 3948 TS7780 Features for requirements and other information.
FC AGKY, Ship with R6.0 Machine Code
Instructs Manufacturing to load the latest manufacturing level of Release 6.0 machine code on the TS7780. For Field orders of R6.0 machine code #AGKY, microcode 'MUST' be ordered via Super Shipper. The Field order of #AGKY will allow for R6.0 machine code level prerequisite requirements on certain hardware features. This feature in itself will not provide microcode items. A one-page flyer with instruction on how to order machine code via Super Shipper will be provided.
Refer to FC AGKY in 3948 TS7780 Features for requirements and other information.
FC AHY2, Onsite Code Load Service for Premium Expert Care
This feature is an indicator that the remote code load upgrades in the unit will be done onsite. This feature is an option for Premium Expert Care only. IBM reserves the right to modify the machine records associated with feature AHY2, based on the actual method used to update code on the customer's unit. Each system, when choosing Premium Expert Care has an option to order AHY2 as remote code load is included as the default standard with Premium Expert Care.
Refer to FC AHY2 in 3948 TS7780 Features for requirements and other information.
FC AHY3, Onsite Code Load Service for Warranty and Advanced Expert Care
This feature is an indicator that the remote code load upgrades in the unit will be done onsite. This feature is an option for Warranty and Advanced Expert Care. IBM reserves the right to modify the machine records associated with feature AHY3 based on the actual method used to update code on the customer's unit. Each system, when choosing Warranty or Advanced Expert Care requires one of features AHY4 or AHY3 to be included.
Refer to FC AHY3 in 3948 TS7780 Features for requirements and other information.
FC AHY4, Remote Code Load Service for Warranty and Advanced Expert Care
This feature is an indicator that the code load upgrades in the unit will be done remotely. This feature is an option for Warranty and Advanced Expert Care. IBM reserves the right to modify the machine records associated with feature AHY4, based on the actual method used to update code on the customer's unit. Each system, when choosing Warranty or Advanced Expert Care requires one of features AHY4 or AHY3 to be included.
Refer to FC AHY4 in 3948 TS7780 Features for requirements and other information.
FC AKCH, Shipping and Handling – Standard
This feature indicates the order will have a standard shipping and handling charge added to the order.
Refer to FC AKCH in 3948 TS7780 Features for requirements and other information.
FC AKCJ, Shipping and Handling - No charge exception
This feature indicates the order will have a standard shipping and handling charge added to the order.
Refer to FC AKCJ in 3948 TS7780 Features for requirements and other information.
FC AKCJ, Shipping and Handling - Premium
This feature is an exception and indicates no shipping and handling charge added to the order.
Refer to FC AKCJ in 3948 TS7780 Features for requirements and other information.
FC AKNC, Shipping and Handling - Premium
This feature indicates the order will have a standard shipping and handling charge added to the order.
Refer to FC AKNC in 3948 TS7780 Features for requirements and other information.
FC I-listed RPQ 8B3723, TS7780 - 3 PHASE POWER cord
iRPQ 8B3723 provides a pair of 415 volt three-phase WYE power cables for FC# 1913, transforming FC $1913 into a 3 phase PDU for use in the TS7780. The cable is 4.3-meters (14.1-feet) long. The cable ships with the following connector: Hubbell Part Number: C532P6W. Male, Plug, 32A 220/380-240/415V, 4-Pole 5-Wire Grounding, Screw Terminals, Red, C-Series, Water-tight. This RPQ requires lab approval before ordering. Note when three-phase is selected the frame UPO switch will no longer control any power for the frame.
Refer to FC I-Listed RPQ 8B3723 in 3948 TS7780 Features for requirements and other information.
FC RPQ 8B3721, TS7780 - TS7780 CLIENT SUPPLIED RACK
The RPQ will need to be ordered for the TS7780 (VEF only) and 3948 (CFD and XSD only).
Refer to FC RPQ 8B3721 in 3948 TS7780 Features for requirements and other information.
FC RPQ 8B3723, TS7780 - 3 PHASE POWER (cord)
RPQ 8B3723 provides a pair of three-phase PDUs for TS7770 3948-F07 for clients who need 400 volts support. It provides a pair of 415 volt three-phase WYE power cables for TS7770 3948-F07. The cable is 4.3 meters (14.1-feet) long and ships with the connectors: Hubbell Part Number: C532P6W. Male, Plug, 32A 220/380-240/415V, 4-Pole 5-Wire Grounding, Screw Terminals, Red, C-Series, Water-tight. This RPQ requires lab approval before ordering. When three-phase is selected, the frame UPO switch will no longer control any power for the frame. Instead, power should be removed for each three-phase PDU.
Refer to FC RPQ 8B3723 in 3948 TS7780 Features for requirements and other information.
FC RPQ 8B3749, TS7780 CLIENT SUPPLIED RACK
- The RPQ will need to be ordered for the TS7780 (VEF only) and 3948 (CFD and XFD only).
- Valid configurations are TS7780 solutions with 1 CFD and up to 10 XFD SSD flash expansion enclosures.
Refer to FC RPQ 8B3749 in 3948 TS7780 Features for requirements and other information.
Feature | Minimum | Maximum | Requirements | Installation | Removable? |
---|---|---|---|---|---|
FC 0201, 9 Micron LC/LC 31 Meter | 0 | 8 (Initial order maximum: 8) | Limitations:
|
Plant / Field installable: Both | Yes |
FC 0203, 50 Micron LC/LC 31 Meter | 0 | 8 (Initial order maximum: 8) | Prerequisite: None Limitation:
|
Plant / Field installable: Both | Yes |
FC 0983, TAA Compliance | 0 | 1 (Initial order maximum: 1) |
Limitations:
|
Plant / Field installable: Initial | No |
FC 1034, Enable Second Port Grid Connection | 0 | 1 (Initial order maximum: 1) | Prerequisites: #1042 or #1043 are required. | Plant / Field installable: Both | Yes |
FC 1042, 1Gb Grid Quad Port Copper Connection | 0 | 2 (Initial order maximum: 2) | Prerequisite: AGKY Limitation: Mutually exclusive with #1043. Comments: Two of #1042 or #1043 are required. |
Plant / Field installable: Both | Yes |
FC 1043,10 GB Dual Port Grid Optical LW Connection | 0 | 2 (Initial order maximum: 2) | Prerequisite: AGKY Limitation: Mutually exclusive with #1042. Comments: Two of #1042 or #1043 are required. |
Plant / Field installable: Both | |
FC 1776, US RoHS | 0 | 1 (Initial order maximum: 1) | None | Plant / Field installable: Plant | Non- applicable |
FC 1913, Single Phase Power Distribution Unit (F08) | 0 | 1 (Initial order maximum: 1) | Prerequisite: One of FC 7337, FC 7338, or FC 7339 is required. Limitations:
Comment:
|
Plant / Field installable: Initial | No |
FC 1913, Single Phase Power Distribution Unit | 0 | 1 (Initial order maximum: 1) | Prerequisite: One of FC 9954, FC 9955, FC 9956, FC 9957, FC 9958, FC 9959 or
FC 9966 is required. Corequisite: FC 4643 or FC 4649 Rack Mount kit VED. Comment: Minimum is one #1913 for single or 3 phase power use. |
Plant / Field installable: Plant | No |
FC 2749, Lock and Key for 3948-F07, 3952-F07, and 3938-F08 | 0 | 1 (Initial order maximum: 1) | Prerequisites: 3948-F07, 3952-F07, and/or 3948-F08. | Plant / Field installable: Both | |
FC 2750, Top Exit Cabling | 0 | 1 (Initial order maximum: 1) | Prerequisites: 3948-F07, 3952-F07, and/or 3948-F08. | Plant / Field installable: Both | |
FC 3401, Enable FICON second port | 0 | 1 (Initial order maximum: 1) | Prerequisites: FC 3404 or FC 3405 is required. Customer setup: Yes Corequisite:
|
Plant / Field installable: Both | No |
FC 3404, 32 Gb SW FICON Adapter | 0 | 4 (Initial order maximum: 4) | Compatibility conflicts: OM4 cable is required for 32 Gb FICON connections.
Limitations:
Comments:
|
Plant / Field installable: Both | |
FC 3405, 32 Gb LW FICON Adapter | 0 | 4 (Initial order maximum: 4) |
Limitations:
|
Plant / Field installable: Both | |
FC 3480, Additional 64GB memory for VEF | 0 | 4 (Initial order maximum: 4) |
Corequisite: AGKY Comments:
|
Plant / Field installable: Both | |
FC 4015, Grid Enablement | 0 | 1 (Initial order maximum: 1) | None | Plant / Field installable: Both | No |
FC 4016, Remove Cluster from Grid | 0 | 99 (Initial order maximum: 99) | Prerequisite: FC 4015 Comments: Includes documentation only. |
Plant / Field installable: Both | No |
FC 4017, Cluster Cleanup | 0 | 99 (Initial order maximum: 99) |
Comments: Not installed but given the key for future use. |
Plant / Field installable: Both | No |
FC 4643, Rack Mount Kit Virtualization engine with common controller | 0 | 1 (Initial order maximum: 1) | Prerequisite:
|
Plant / Field installable: Plant | No |
FC 4647, Rack Mount Kit Common Controller | 0 | 1 (Initial order maximum: 1) | Prerequisites:
Limitations: Mutually exclusive with #9352 or #9353. |
Plant / Field installable: Plant | No |
FC 4648, Rack Mount Kit XSD | 0 | 1 (Initial order maximum: 1) | Prerequisites:
Limitations: Mutually exclusive with #9354 or #9355. |
Plant / Field installable: Initial | No |
FC 4649, Rack Mount Kit VEF with CFD | 0 | 1 (Initial order maximum: 1) | Prerequisites:
Limitations:
|
Plant / Field installable: Initial | No |
FC 4694, Initial Order XSD Customer Rack | 0 | 10 (Initial order maximum: 10) | Corequisite: FC 4643 Rack Mount Kit VEF. Limitation:
|
Plant / Field installable: Initial | No |
FC 4650, Rack Mount Kit for Common Controller | 0 | 1 (Initial order maximum: 1) | Prerequisite:
Limitation: Mutually exclusive with FC 9352. |
Plant / Field installable: Initial | No |
FC 4651, Rack Mount Kit Expansion Cache Drawer for SSDs | 0 | 1 (Initial order maximum: 1) | Prerequisite:
Limitation: Mutually exclusive with FC 9354 or FC 9355. |
Plant / Field installable: Initial | |
FC 4698, Initial Order XFD Customer Rack | 0 | 10 | Corequisite: #4649 Rack Mount Kit VEF. Limitation: Valid quantities of #4698 are 0 - 10. |
Plant / Field installable: Initial | No |
FC 4699, Field Order XFD for Customer Rack | 0 | 9 | Corequisite: #4649 Rack Mount Kit VEF. Limitation: Valid quantities of #4698 and #4699 are 1 - 9. |
Plant / Field installable: MES | No |
FC 4881, 32GB FC switch for Tape Library connectivity | 0 | 1 (Initial order maximum: 1) | Prerequisite: Require #5881 or #5882 on 3948-F08 Corequisite: #5273 Costumer setup: No Comments:
|
Plant / Field installable: Both | Yes |
FC 5244, Quad Port 32 Gb FC HBA | 0 | 1 (Initial order maximum: 1) | Prerequisite: #9336 (1st Expansion Frame Attach) is required on
the 3948-F08 where this 3948-VEF is installed when #5243 equals one. Conflicts: Not available with 3948- #7339 SSD based TS7780s. Comments: Can only be used with CFD/XSD or HDD configurations. |
Plant / Field installable: Both | |
FC 5262, 20 TB cache enablement | 0 | 99 (Initial order maximum: 4) | Customer set up : Yes Limitations:
Comments:
|
Plant / Field installable: Both | No |
FC 5263, 100TB cache enablement | 0 | 80 (Initial order maximum: 80) | Customer setup: Yes Limitations:
|
Plant / Field installable: Both | No |
FC 5268, 100 MB/sec Increment | 0 | 39 (Initial order maximum: 39) |
Customer setup: Yes |
Plant / Field installable: Both | No |
FC 5270, Increased Logical Volumes | 15 | 15 (Initial order maximum: 15) | All 3948-VEF will come standard with a full complement of 4M logical volumes. Comments: In a grid configuration where there are Clusters with smaller number of logical volumes, the 3948-VEF will be limited to the cluster with the smallest number of logical volumes. |
Plant / Field installable: Plant | No |
FC 5271, Selective Device Access Control | 0 | 2 (Initial order maximum: 2) |
Comments: Qty 1 x 5271 allows 8 + default access group, with Qty 2 x 5271 allows 16 + default group. |
Plant / Field installable: Both | No |
FC 5272, Disk Enabled Encryption | 0 | 1 (Initial order maximum: 1) | Customer Setup: No Prerequisite: When feature #5272 is installed, feature #7405 is required on each 3948-CFD model in the TS7780 cluster.Limitations: #5272 is not available in the following countries: Armenia, Belarus, Kazakhstan, Kyrgyzstan, and Russia. |
Plant / Field installable: Plant | No |
FC 5273, TS7780 Tape Attach | 0 | 1 (Initial order maximum: 1) | Prerequisite: At least 1 x #5274 or #5279 is required. Corequisite: #4881 or #4880. Limitation: Mutually exclusive with #5278. Comments: If using #4880 you will need to purchase Qty 2 for redundancy. #4881 includes 2 switches. |
Plant / Field installable: Both | No |
FC 5274, Enable 1 TB Pending Tape Capacity | 0 | 10 (Initial order maximum: 10) | Corequisite: Feature #5273 or #5278 is required. Customer setup: Yes Comments:
|
Plant / Field installable: Both | No |
FC 5275, Additional virtual devices | 0 | 15 (Initial order maximum: 15) |
Customer setup: Yes Comment: TS7780 microcode includes 256 virtual devices as default. |
Plant / Field installable: Both | No |
FC 5276, Disk Encrypt-External Key Manager | 0 | 1 | Prerequisites:
Limitations: Feature #5276 is not available in the following countries: Armenia, Belarus, Kazakhstan, Kyrgyzstan, and Russia. Customer setup (CSU): No |
Plant / Field installable: Both | No |
FC 5278, Cloud Enablement | 0 | 1 (Initial order maximum:1) | Corequisite: At least 1 x #5274 is required. Limitations: Mutually exclusive with #5273. Comments: 3 x #5274 is the recommended minimum premigration queue size. Customer setup: No |
Plant / Field installable: Both | No |
FC 5279, 5 TB Active Premigration Queue | 0 | 10 (Initial order maximum: 10) | Prerequisite: 10 x #5274 are required before the first instance of #5279 may be
installed. Corequisite: Feature #5273 or #5278 is required. Customer setup: Yes Limitation: 10 x #5274 are required before the first instance of #5279 may be installed. Comments: Once 10 x #5279 are installed, the amount of data pending active premigration for tape or cloud is no longer constrained by features #5274 and #5279. |
Plant / Field installable: Both | No |
FC 5281, Secure Data Transfer | 0 | 1 | Prerequisite: Feature #4015. Customer setup: Yes Comment: #5281 (SDT) is required on any cluster sending or receiving encrypted data across a grid link. |
Plant / Field installable: Both | Yes |
FC 5283, TS7780 Advanced Object Store for DS8000 | 0 | 1 (Initial order maximum: 1) |
Limitations: FC #5283 supports TCT object data moving to disk only. The cluster may have #5273 / #5278 installed but does not support moving TCT Object data to tape or cloud. Future support for Tape or Cloud as a tier for TCT object data is expected in a future release. |
Plant / Field installable: Both | No |
FC 5290, Tape tools (Default and mandatory) | 1 | 1 (Initial order maximum: 1) | Prerequisites: AGKY Comments:
|
Plant / Field installable: Plant | |
FC 5291, Service Access Control | 0 | 1 (Initial order maximum: 1) | Prerequisites: AGKY Customer setup: Yes Comments:
|
Plant / Field installable: Both | |
FC 5631, Install 3948 Virtualization Engine | 1 | 1 (Initial order maximum: 1) | Prerequisites:
Customer setup: No Comments:
|
Plant / Field installable: Initial | No |
FC 5663, Plant Install 3948 Controller Drawer | 1 | 1 (Initial order maximum: 1) | Prerequisites:
Customer setup: No Limitations:
Comments: When installing a 3948-CFD common controller in #7337 and #7338 at least 2 XSDs (HDD) must be added in each initial string. When installing a 3948-CFD common controller in a #7339 at least 1 XFD (SSD) must be added to the initial string. Also note that FC #5757 must be added to the 1st Expansion Frame when adding the 1st CFD into the same expansion frame. |
Plant / Field installable: Initial | No |
FC 5664, Plant Install 3948 Expansion cache drawer for HDDs | 0 | 10 (Initial order maximum: 10) | Prerequisites:
Limitations:
|
Plant / Field installable: Initial | No |
FC 5665, Field Install 3948 Expansion cache drawer for HDDs | 0 | 10 (Initial order maximum: 10) | Prerequisites:
Limitations:
|
Plant / Field installable: MES | No |
FC 5666, Field Install 3948 CFD | 0 | 1 (Initial order maximum: 1) | Prerequisites:
Comment:
|
Plant / Field installable: MES | No |
FC 5668, Plant Install 3948 Expansion cache drawer for SSDs | 0 | 10 (Initial order maximum: 10) | Prerequisites:
|
Plant / Field installable: Initial | No |
FC 5669, Field Install 3948 for Expansion cache drawers for SSDs | 0 | 9 (Initial order maximum: 9) | Prerequisites:
Limitation: Valid quantities with #7339 of #5663 plus #5668 plus #5669 are 3 through 11. |
Plant / Field installable: MES | No |
FC 5757, Integrated Network Control Path | 0 | 1 (Initial order maximum: 1) | Prerequisites: Feature #7337 and / or #7339 | Plant / Field installable: Plant | |
FC 5881, Plant Install 32GB FC switch for Tape Library connectivity | 0 | 1 (Initial order maximum: 1) | Prerequisite: #4881 on 3948-VEF Corequisite: #5273 on 3948-VEF |
Plant / Field installable: Plant | |
FC 5882, Field Install 32GB FC switch for Tape Library connectivity | 0 | 1 (Initial order maximum: 1) | Prerequisite: #4881 on 3948-VEF Corequisite: #5273 on 3948-VEF |
Plant / Field installable: Field | |
FC 5995, zTape Air-Gap with LTO | 0 | 1 | Prerequisite:
Limitations: FC 5273, FC 5278, and FC 5283. Comment:
|
Plant / Field installable: Both | No |
FC 7120, 240 TB SAS Storage | 1 | 1 (Initial order maximum: 1) | None | Plant / Field installable: Initial | |
FC 7123, 360 TB SSD FLASH Expansion Storage | 1 | 1 (Initial order maximum: 1) | None | Plant / Field installable: Initial | |
FC 7337, TS7780 HDD based Encryption Capable Base Frame | 0 | 1 (Initial order maximum: 1) |
Compatibility conflicts: Mutually exclusive with all other #7339 features. Prerequisites:
|
Plant / Field installable: Initial | No |
FC 7338, TS7780 Encryption Capable Expansion Frame | 0 | 1 (Initial order maximum: 1) | Compatibility conflicts: Mutually exclusive with all other #73xx features. Prerequisites:
Corequisite: Power Distribution Unit #1913 is required. Limitations:
Comments:
|
Plant / Field installable: Both | No |
FC 7339, TS7780 Encryption Capable SSD Base Frame (F08) | 0 | 1 (Initial order maximum: 1) | Prerequisites:
Compatibility conflicts: Mutually exclusive with all other #73xx features Customer setup: No Limitations: When #5663 is present, valid quantities of #5663 and #5668, or #5669 are 2-11. |
Plant / Field installable: Initial | No |
FC 7405, Encryption CFD (USB Flash Drives (Four Pack)) | 0 | 1 | Prerequisite: Required when #5272 or #5276 is installed on the 3948-VEF TS7780 server. Limitations:
|
Plant / Field installable: Plant only | No |
FC 9000, Mainframe Attachment | 1 | 1 (Initial order maximum: 1) | None | Plant / Field installable: Initial | No |
FC 9219,Tape Library Attach | 0 | 1 (Initial order maximum: 1) | Corequisite: FC 5273 is required. Comment: 2 x #4881 are recommended for redundancy. |
Plant / Field installable: Both | Yes |
FC 9268, Plant installation of 100 MB/s Throughput | 1 | 1 (Initial order maximum: 1) | None. | Plant / Field installable: Initial | No |
FC 9336, TS7780 1st Expansion Frame Attachment | 0 | 1 (Initial order maximum: 1) |
Prerequisites:
|
Plant / Field installable: Both | No |
FC 9339, Replacing TS7700 Tape Attach System | 0 | 1 (Initial order maximum: 1) | Prerequisite: Feature #5273 is required on the 3948-VEF installed in this model F08. | Plant / Field installable: Plant | No |
FC 9350, Plant Install | 0 | 1 (Initial order maximum: 1) | Prerequisite: Feature #5631 on 3948 Model F08 is required. Limitations: Mutually exclusive with #4643 or #4649 |
Plant / Field installable: Plant | No |
FC 9352, Plant Install Common Controller Drawer | 0 | 1 | Prerequisite: One of #9352 or #4650 is required Limitations: Mutually exclusive with #4650 (Rack Mount) This feature must appear on the TS7780 Model CFD order and the Plant Install feature (5663) must appear on the 3948 F08 Frame order. |
Plant / Field installable: Plant only | No |
FC 9354, Plant Install for expansion cache drawer for SSDs. | 0 | 1 | Prerequisite: One of #4648 or #9354 or #9355 is required Limitation:
|
Plant / Field installable: Plant only | No |
FC 9354, Plant Install for expansion cache drawer for HDDs. | 0 | 1 | Prerequisite: One of #4651 or #9354 or #9355 is required Limitation:
|
Plant / Field installable: Plant only | No |
FC 9355, Field merge expansion cache drawer for SSDs | 0 | 1 |
Prerequisite: One of #4651 or #9354 or #9355 is required. Limitation:
|
Plant / Field installable: Plant only | No |
FC 9355, Field merge expansion cache drawer for HDDs | 0 | 1 |
Prerequisite: One of #4648 or #9354 or #9355 is required. Limitation:
|
Plant / Field installable: Plant only | No |
FC 9700, No Factory Cables | 0 | 1 (Initial order maximum: 1) | None. | Plant / Field installable: Plant | No |
FC 9900, Tape Encryption Config | 0 | 1 (Initial order maximum: 1) | Prerequisite: #5273 Customer Setup: Yes. Limitation: Feature #9900 is not available in Armenia, Belarus, Kazakhstan, Kyrgyzstan, and Russia. |
Plant / Field installable: Both | No |
FC 9954, NEMA L6-30 Power Cord | 0 | 2 (Initial order maximum: 2) |
Limitations: One of 9954, 9955, 9956, 9957, 9958, 9959, or 9966 is required. Comment: Includes 1 cable. |
Plant / Field installable: Both | Yes |
FC 9955, RS 3750 DP Power Cord | 0 | 2 (Initial order maximum: 2) |
Limitations: One of 9954, 9955, 9956, 9957, 9958, 9959, or 9966 is required. Customer setup: No Comment: Includes 1 cable. |
Plant / Field installable: Both | Yes |
FC 9956, IEC 309 Power Cord | 0 | 2 (Initial order maximum: 2) |
Limitations: One of 9954, 9955, 9956, 9957, 9958, 9959 or 9966 is required. Customer setup: No Comment: Includes 1 cable. |
Plant / Field installable: Both | Yes |
FC 9957, PDL 4.3 Power cord | 0 | 2 (Initial order maximum: 2) |
Limitations: One of 9954, 9955, 9956, 9957, 9958, 9959, or 9966 is required. Customer setup: No Comment: Includes 1 cable. |
Plant / Field installable: Both | Not applicable |
FC 9958, Korean 4.3 Power cord | 0 | 2 (Initial order maximum: 2) |
Limitations: One of 9954, 9955, 9956, 9957, 9958, 9959, or 9966 is required. Customer setup: No Comment: Includes 1 cable. |
Plant / Field installable: Both | Not applicable |
FC 9959, Unterminated Power cord | 0 | 2 (Initial order maximum: 2) | One of 9954, 9955, 9956, 9957, 9958, 9959, or 9966 is required Comment: Includes 1 cable. |
Plant / Field installable: Both | Not applicable |
FC 9966, China Unterminated Power Cord | 0 | 2 (Initial order maximum: 2) |
Limitations: One of 9954, 9955, 9956, 9957, 9958, 9959, or 9966 is required. Customer setup: No Comment: Includes 1 cable. |
Plant / Field installable: Both | Not applicable |
FC AKCJ Shipping and Handling- No Charge Exception | 0 | 1 (Initial order maximum: 1) | Prerequisites: Feature #4650 Limitations:
Comments: Premium Shipping and Handling is the default for all TS7780 installations. |
Plant / Field installable: Initial | |
FC AKCJ Shipping and Handling- Premium | 0 | 1 (Initial order maximum: 1) | Prerequisites: Feature #4650 Limitations:
Comments: Premium Shipping and Handling is the default for all TS7780 installations. |
Plant / Field installable: Initial | |
FC AKCH Shipping and Handling- Standard | 0 | 1 (Initial order maximum: 1) | Prerequisites: Feature #4650 Limitations:
Comments: Premium Shipping and Handling is the default for all TS7780 installations. |
Plant / Field installable: Initial | |
FC AKNC Shipping and Handling- Premium | 0 | 1 (Initial order maximum: 1) | Prerequisites: Feature #4650 Limitations:
Comments: Premium Shipping and Handling is the default for all TS7780 installations. |
Plant / Field installable: Initial | |
(For 3948-F07) FC AGKY - R6.0 Machine Code | 0 | 1 (Initial order maximum: 1) | Prerequisites: Feature #7339 and/or #7337 is required. | Plant / Field installable: Field | |
(For 3948-VED) FC AGKY - R6.0 Machine Code | 0 | 1 (Initial order maximum: 1) | Prerequisites: Feature #7339 and/or #7337 is required. | Plant / Field installable: Field | |
FC AGKY - R6.0 Machine Code | 1 | 1 (Initial order maximum: 1) | None | Plant / Field installable: Plant | |
FC AHY2 - Onsite Code Load Service for Premium Expert Care | 0 | 1 (Initial order maximum: 1) | Prerequisites: Premium Expert Care. | Plant / Field installable: Both | |
FC AHY3 - Onsite Code Load Service for Warranty and Advanced Expert Care | 0 | 1 (Initial order maximum: 1) | Prerequisites: Warranty or Advanced Expert Care. Limitations: Must have one #AHY4 or #AHY3. |
Plant / Field installable: Both | |
FC AHY4 - Remote Code Load Service for Warranty and Advanced Expert Care | 0 | 1 (Initial order maximum: 1) | Prerequisites: Warranty or Advanced Expert Care. Limitations: Must have one #AHY4 or #AHY3 |
Plant / Field installable: Both | |
FC RPQ 8B3723, TS7780 - 3 PHASE POWER (cord) | 0 | 1 | Prerequisites: #1913 is required. Limitations: Mutually exclusive with #9954, #9955, #9956, #9957, #9958, #9959, and #9966 |
Plant / Field installable: Plant only | No |