HYDIN0066I (OP0066) One or more volumes have been inserted into the library and marked unassigned.

Explanation

The library is in import mode and physical volumes have been inserted into the library through the convenience I/O station. These physical volumes have been marked as unassigned and should be defined using the Physical->Physical Volumes->Physical Volume Ranges page.

Operator response

  • If attached to a 3584 attached library, use the Physical->Physical Volumes->Physical Volume Ranges panel on the TS7700 Engine Management Interface to (1) eject this volume or (2) adjust the ranges of defined physical volumes.

Source

Physical Cartridge