HYDIN0031W (OP0031)Device device identifier is not ready.
Operator response
Place the library system in pause mode.
Open the enclosure.
If the cartridge is in a CST/ECCST type device (model C1A or C2A), make the device not ready by
pressing the Ready button. Press the Unload button to unload the cartridge, remove the cartridge,
and make the device ready by pressing the Ready button.
If the drive does not become ready, call your service representative. If a check code appears on
the message display, record the code and report it to your service representative.
If the cartridge is in a CST/ECCST type device (model F1A), press the Load/Unload button to
unload the cartridge, remove the cartridge.
If the cartridge is in a HPCT/EHPCT type device, select Unload from the Options Menu and press
Enter. Remove the cartridge.
If a check code appears on the message display, record the code and report it to your service
representative.
Place the cartridge in the error recovery cell. The error recovery cell is cell 1A1 (Cell 1A3 if
dual grippers are installed in the library).