Inquiry Standard Data: Invalid LUN (DLT Control Port Only)
The following tape
library-specific parameters apply
to this request:
- CmdDt: B'0'
- EVPD (Enable Vital Product Data): B'0'
- Page Code: X'00'
- Allocation Length: X'24' (36) bytes available
Table 1 shows the standard inquiry data that is returned (character fields are in ASCII) for a LUN that is not associated with an installed device. For more detail, go to the section about default SCSI ID and Loop ID (AL_PA) assignments for the tape library.
Byte | Bit 7 | Bit 6 | Bit 5 | Bit 4 | Bit 3 | Bit 2 | Bit 1 | Bit 0 |
---|---|---|---|---|---|---|---|---|
0 | Peripheral Qualifier (B'011') | Peripheral Device Type (X'1F') | ||||||
1 | RMB (B'0') | Reserved | ||||||
2 | ISO/IEC Version (B'00') | ECMA Version (B'000') | ANSI Approved Version (B'011') | |||||
3 | AERC (B'0') | Obsolete (B'0') | NormACA (B'0') | HiSupport (B'0') | Response Data Format (B'0010') | |||
4 | Additional Length (n-4) (X'1F' or 31 bytes) | |||||||
5 | SCCS (B'0') | Reserved | ||||||
6 | BQue (B'0') | EncServ (B'0') | BarC (B'1') | MultiP (B'0') | MChngr (B'0') | AckReqQ (B'0') | Addr32 (B'0') | Addr16 |
7 | RelAdr (B'0') | WBus32 (B'0') | WBus16 | Sync | Linked (B'0') | TranDis (B'0') | ComQue (B'0') | SftRe (B'0') |
8-15 | Manufacturer ('IBM ') (in ASCII) | |||||||
16-31 | Device Type and Model Number | |||||||
32-35 | Product Revision Level |
- Device Type and Model Number: ASCII blanks are returned.
- Product Revision Level: ASCII blanks are returned.