Cleaning Cartridge Presence Indicators in the Tape Library
The tape library can monitor up
to 100 cleaning cartridges in the physical library for any supported method of cleaning. See the
section about cleaning the drive in the TS4500 Introduction and Planning
Guide. The presence of a library-monitored cleaning cartridge is indicated in the
Storage Element descriptor of Read Element Status data as follows:
- EXCEPT bit is set to
1
- FULL bit is set to
1
- ASC/ASCQ field is set to
30/03
- The first, second, and third characters of the Primary Volume Tag field,
if available, are set to
CLN
in ASCII
0
;
when automatic cleaning is disabled, the ACCESS bit is set to 1
.While an automatic cleaning is in progress, movement of the cleaning cartridge is not reflected
in the element descriptors. The Storage Element descriptor reported for the cleaning cartridge slot
does not change while the cleaning cartridge is in a drive. Similarly, the Data Transfer Element
descriptor reported for the drive that is cleaning does not change (indicates the FULL bit set to
0
).
While a host cleaning is in progress, movement of the cleaning cartridge is reflected in the element descriptors in the same manner as for a data cartridge.