Restoring IMM default settings for the TS7650 Appliance or TS7650G (Gateway), ProtecTIER V3.3.6

Complete this task to restore the IMM default settings on the ProtecTIER® server.

Procedure

Perform the following steps to reset the IMM to default values:

  1. From the login prompt at the command line, log in to the node as ptadmin/ptadmin.
  2. At the command line, enter menu to access the ProtecTIER Service menu.
  3. From the ProtecTIER Service menu, select Manage ProtecTIER services > Stop all services.
  4. When all services are DOWN, press Enter to return to the menu, then type E to exit the menu.
  5. Shut down the vtfd services by entering the following command:
    service vtfd shutdown

    The vtfd service completes the shutdown.

  6. Reboot the node by entering the following command:
    reboot
  7. During the reboot sequence, when presented on-screen to enter a function key to enter Setup, press F1.
  8. Under System Settings, select Integrated Management Module > Reset the IMM to Defaults.
  9. Press F10 to Save and Exit. The system reboots.
  10. When the system recovers and returns to the command line, log in as ptadmin/ptadmin.
  11. Enter menu to access the ProtecTIER Service menu.
  12. From the ProtecTIER Service menu, select ProtecTIER Configuration > Configure RAS.
  13. Follow, and enter in the relevant data to configure RAS on the node.
  14. If this is a clustered system, the Configure RAS option must be run on both servers to update the IMM settings with the correct IP addressing for connection to the TSSC.
Terms of use Support Feedback
Copyright IBM Corporation 2010, 2011.
Powered by Eclipse Technology. This product includes software developed by the Eclipse Project (http://www.eclipse.org/).