CKM02452W PROCESSING FOR uuuuuuuu HAS BEEN TERMINATED
Explanation
While unloading data for a catalog, a fatal error caused BACKUP to stop processing the catalog "uuuuuuuuuu".
User response
This error was detected by the Catalog Fast Reader Module and reported by the Error Summary Module. Numerous CKM341xxI messages accompany this message.
If "NOEXAMINE" was not coded
and EXAMINE did not detect errors, it is possible that the catalog
was successfully backed up. To determine if this the case, using IDCAMS,
execute EXAMINE explicitly:
//AMS EXEC PGM=IDCAMS
//SYSPRINT DD SYSOUT=*
EXAMINE NAME(...)DTEST
EXAMINE will issue several
messages. Find the message IDC01710I DATA COMPONENT CONTAINS nnn RECORDS.
Compare the nnn value to the total records unloaded
by BACKUP which is indicated in the message
CKM02446I RECORD SUMMARY FOR catalogname
If the counts are the same, the BACKUP was successful and no further action is necessary. If the symptom persists, a permanent solution would be to RECOVER the catalog.
If the counts are different, the BACKUP was not successful. Contact Technical Support. Ensure that this entire job stream, including JCL, and all messages are available for the support staff.