Explanation
Audit Suite has compared the catalog extraction against
the MCDS MCD extraction and has determined that even though the data
set is cataloged, and the MCD exists, the high level node(s) of the
data set is not connected to the master catalog and therefore can
not be recalled. This error will also be generated for any data set
that is cataloged in the master catalog that does not have a high
level node of SYS1. Although these data sets can be recalled, IBM
recommends that the master catalog should contain only entries for
user catalogs, their aliases and system, or 'SYS1' data sets.
User response
There is no recommended default fix.FIELD # DESCRIPTION EXAMPLE
FIELD 1 ERROR NUMBER 1117C
FIELD 2 DSNAME XAS.VSAMMLIB
FIELD 3 HSM VOLSER MIGRAT
FIELD 4 CATALOG NAME UCAT.TECH
FIELD 5 CREATION DATE 2000198