1109W MCD ALIAS IS NOT ON TTOC

Explanation

Audit Suite has compared the MCDS MCD extraction (Level 2) against the HSM OCDS TTOC extraction and has been unable to find a matching HSM generated alias name in the TTOC. HSM does not use the TTOC information during Recall but these errors may indicate a general health problem in the HSM environment. This can also be the result of an incomplete TTOC update resulting from an HSM ABEND or system crash or an IPL over a working HSM. This problem will impact the tape recycle process.
Note: Audit Suite does not verify these errors in real time. If recycle was running while the audit was extracting information, these errors may be erroneous. For best results, make sure recycle is not running at the same time as Audit Suite.

User response

Run the AUDIT MEDIACONTROLS for complete analysis.
FIELD # DESCRIPTION            EXAMPLE
FIELD 1 ERROR NUMBER           1109W
FIELD 2 DSNAME                 DRS.ICS91102.CLIST
FIELD 3 HSM GENERATED NAME     HSM.HMIG.T472104.dsn
FIELD 4 HSM VOLSER             HM0017
FIELD 5 VSAM/NVSAM             N
FIELD 6 HSM LEVEL              2