Setting log information levels

In the TRIRIGAWEB.properties file, system administrators can specify the level of logging detail in the GRAPHICS_SECTION_LOGGING_LEVEL property.

Procedure

  1. Open the install_home/config/TRIRIGAWEB.properties file.
  2. Specify the value for the GRAPHICS_SECTION_LOGGING_LEVEL property.
    The following values are valid values for the property.
    INFO
    Log all messages from all events
    WARN
    Log only warning and error messages
    ERROR
    Log only error messages
  3. Save the file.
  4. Restart the server.