The following two tables contain specifications for multimode trunk cable support attachment of FICON® SX-capable, or coupling facility channel-capable devices. Use of trunk fiber having different specifications significantly alters link characteristics. Be sure to use the specification corresponding to the operating wavelength of the channel.
| 62.5/125-μm multimode trunk cable | |
|---|---|
| Type of fiber | Graded index with glass core and cladding |
| Core diameter1 | 62.5 ±3.0 μm |
| Core noncircularity | 6% maximum |
| Cladding diameter2 | 125 ±3.0 μm |
| Cladding noncircularity | 2% maximum |
| Core and cladding offset | 3μm maximum |
| Numerical aperture3 | 0.275 ± 0.015 |
| Minimum modal bandwidth4 | 500 MHz∙ km at ≤ 2 km at 1300 nm or 160 MHz∙ km at 850 nm 800 MHz∙ km at > 2 km and ≤ 3 km at 1300 nm |
| Attenuation5 | 1.0 dB/km at 1300 nm 4.0 dB/km at 850 nm |
| Notes:
|
|
| 50.0/125-μm multimode trunk cable | |
|---|---|
| Type of fiber | Graded index with glass core and cladding |
| Core diameter 1 | 50.0 ±3.0 μm |
| Core noncircularity | 6% maximum |
| Cladding diameter2 | 125 ±3.0 μm |
| Cladding noncircularity | 2% maximum |
| Core and cladding offset | 3μm maximum |
| Numerical aperture3 | 0.200 ± 0.015 |
| Minimum modal bandwidth4 | 800 MHz• km at ≤ 2 km at 1300 nm or 500 MHz• km at ≤ 1 km at 850 nm |
| Attenuation5 | 0.9 dB/km at 1300 nm or 3.0 dB/km at 850 nm |
|