ICP234I INVALID MIX OF CHPID TYPES WERE SPECIFIED FOR THIS CONTROL UNIT
Explanation
An entry for a control unit contains an incorrect
mixture of channel path types (TYPE keyword). All channel path types
attaching to a control unit must meet the following restrictions:
- All CBY or CVC
- All CNC, FCV, or FC
- CTC
- All CFS or CBS
- All CFP, CBP, ICP, CIB, CL5, or CS5
- FCP
- IQD
- OSC
- OSD
- OSE
- OSM
- OSN
- OSX
System action
IOCP continues to validate and check the syntax of the remaining statements. However, it does not generate an IOCDS and it does not produce configuration reports.
Programmer response
Ensure that all of the channel paths attaching to the control unit are allowed to mix.