ICP217I TOO MANY PNETID PARAMETERS SPECIFIED FOR TYPE=xxxx WHICH HAS A MAXIMUM OF n

Explanation

You specified too many PNETID parameters for channel path or function type xxxx. IOCP limits the number of PNETID parameters to the number of ports that are available for the given channel path or function type which is n. However, the ROC2 function supports two ports but each FID is associated with only one of the ports which is specified with the PORT keyword. Therefore, the ROC2 function type supports only one PNETID for a FID definition.

System action

IOCP continues to validate and check the syntax of the remaining statements. However, it does not generate an IOCDS and it does not produce configuration reports.

Programmer response

Reduce the number of PNETID parameters so they do not exceed the maximum supported.