CPC activation and power-on reset error

CPCs can fail activation or power-on reset (POR) if the selected IOCDS contains an unsupported function or channel path type for the CPC. This situation can occur if your CPC does not yet support a function IOCP permits. The activation or power-on reset fails with error message (ACTZ16F) as follows:
The requested operation cannot be performed because some element of the 
configuration defined in the input/output configuration data set (IOCDS) 
is not supported. xxxxxxxx xxxxxxxx indicates the unsupported function or 
channel type.
See section 'CPC Activation and power-on reset Error' in the 'Machine
Limits and Rules' appendix in the IOCP User's Guide for the supported
functions and channel types. Verify that the IOCDS definition is correct for
this machine EC level.
Contact IBM support for further help.

This CPC error message contains a hexadecimal field that identifies the unsupported function or channel path type. Use the following table to determine which function or channel path type is incorrect for your CPC and write a new IOCDS that does not contain it. Also, the following hexadecimal values describe what the displays when you click Supported I/O Mask under View on the . If there is a mismatch between the Supported I/O mask and the IOCDS mask that the SE displays, an Unsupported mask is displayed that contains only the unsupported functions or channel path types. Also, power-on reset fails with the IOCDS at the current EC.

IOCP message ICP065I also contains a hexadecimal field which identifies unsupported functions or channel path types. The following table lists hexadecimal values and their meanings:

Table 1. Activation and POR error message hexadecimal values
Hexadecimal value Channel path type, function type, or IOCP function
00000000 00000001 OSM
00000000 00000002 OSX
00000000 00000004 CNC
00000000 00000008 CTC
00000000 00000010 CVC
00000000 00000020 CBY
00000000 00000080 CFS
00000000 00000100 CFR
00000000 00000200 CIB
00000000 00001000 CBS
00000000 00002000 CBR
00000000 00004000 FCV
00000000 00008000 FC
00000000 00010000 OSH
00000000 00020000 OSN
00000000 00080000 OSD
00000000 00100000 OSE
00000000 00200000 OSC
00000000 00400000 CFP
00000000 00800000 CBP
00000000 01000000 ICP
00000000 02000000 FCP
00000000 04000000 IQD
00000000 10000000 CS5
00000000 20000000 CL5
00000000 40000000 CL6
00000000 80000000 FUNCTION FID defined (Note 1)
00000001 00000000 ROCE FID
00000002 00000000 ZEDC FID
00000008 00000000 ISM FID
00000010 00000000 RCE FID
00000020 00000000 HYL FID
00000080 00000000 ROC2 FID
00000100 00000000 NVME FID
00000200 00000000 NETH FID
00000400 00000000 NETD FID
00000800 00000000 PAIA FID
01000000 00000000 CHECKCPC=NO or NOCHKCPC
02000000 00000000 MCS_1 partition defined (Note 4)
04000000 00000000 UUID statement specified (Note 3)
08000000 00000000 FC channel path defined with greater than 16384 unit addresses on CNTLUNIT statements (Note 2)
10000000 00000000 PNETID keyword specified (Note 2)
Notes:
  1. This value is set only for 2828 and 2827 models.
  2. This value is set only for 2827 models.
  3. This value is set only for 2965 and 2964 models.
  4. This value is set only for 3907 and 3906 models.