ICP257I ALL COUPLING CHPIDS ATTACHED TO CONTROL UNIT MUST CONNECT TO THE SAME SYSTEM
Explanation
You defined a control unit with CIB, CL5, CL6, or CS5 channel paths (TYPE keyword) where all of the channel paths do not connect to the same target CPC (CSYSTEM keyword on CHPID statement). All CIB, CL5, CL6, and CS5 channel paths in a control unit must have identical CSYSTEM keyword values.
System action
IOCP continues to validate and check the syntax of the remaining statements. However, it does not generate an IOCDS and it does not produce configuration reports.
Programmer response
Ensure that all of the CIB, CL5, CL6, and CS5 channel paths attaching to the control unit all have the same CSYSTEM keyword value.