ICP241I **WARNING** PROTOCL KEYWORD IGNORED FOR CONTROL UNITS ATTACHING TO NON-CVC CHPIDS

Explanation

You specified the PROTOCL keyword for a control unit that attaches to a channel path type other than CVC. IOCP processes the PROTOCL keyword for control units that attach to only CVC channel paths. IOCP ignores the PROTOCL keyword for control units attached to any other type of channel path.

System action

IOCP prints this warning message following the CNTLUNIT statement in question and continues processing.

Programmer response

Either delete the PROTOCL keyword or change the channel path type.