Table 1 shows the availability of
IBM® jumper cables according to, cable type
(single mode [SM], or multimode [MM]), and connector type.
Table 5 shows the availability of
IBM jumper cables according to cable
length.
Standard length SC Duplex connector jumper cables are available from IBM.
Table 1. Available cable and connector types: FICON/FCP, Coupling Links, zHyperLink Express and OSA
| Multimode 50 and 62.5 μm |
Single Mode |
| LC Duplex-to-SC Duplex |
LC Duplex-to-SC Duplex |
| LC Duplex-to-ST |
LC Duplex-to-ST |
| LC Duplex-to-LC |
|
Table 2. OM3 LC to LC multimode Jumpers
| Fixed length part number |
EC |
Length |
| 00LU872 |
N37066 |
256.5 mm +/- 5.5 |
| 00LU873 |
N37066 |
310 mm + 10 |
| 15R7094 |
G42638 |
500 mm / 1.64 ft |
| 45D4773 |
G40909 |
1 m / 3.3 ft |
| 45D2683 |
G36907 |
2 m / 6.6 ft |
| 15R8846 |
G42864 |
3 m / 9.8 ft |
| 45E9750 |
M10504 |
4.2 m / 13.8 ft |
| 45D4774 |
G40909 |
5 m / 16.4 ft |
| 41V2120 |
G40437 |
10 m / 32.8 ft |
| 15R8847 |
G42864 |
15 m / 49.2 ft |
| 41V2121 |
N37299 |
20 m / 65.6 ft |
| 15R8848 |
G42864 |
25 m / 82.0 ft |
| 41T9514 |
G37408 |
30 m / 98.43 ft |
| 41V2122 |
G40437 |
40 m / 131.2 ft |
| 41V2123 |
G40437 |
80 m / 262.5 ft |
| 46K3445 |
G37722 |
100 m / 328.1 ft |
| 41V2124 |
G40437 |
150 m / 492.1 ft |
| 45D2688 |
G36907 |
Custom |
Table 3. OM4 LC to LC multimode Jumpers
| Fixed length part number |
EC |
Length |
| 00LT909 |
N36702A |
500 mm / 1.64 ft |
| 00LT910 |
N36702A |
1 m / 3.3 ft |
| 00LT911 |
N36702A |
2 m / 6.6 ft |
| 00LT912 |
N36702A |
3 m / 9.8 ft |
| 00LT913 |
N36702A |
5 m / 16.4 ft |
| 00LT914 |
N36702A |
10 m / 32.8 ft |
| 00LT915 |
N36702A |
15 m / 49.2 ft |
| 00LT916 |
N36702A |
20 m / 65.6 ft |
| 00LT917 |
N36702A |
25 m / 82.0 ft |
| 00LT918 |
N36702A |
30 m / 98.43 ft |
| 00LT919 |
N36702A |
40 m / 131.2 ft |
| 00LT920 |
N36702A |
80 m / 262.5 ft |
| 00LT921 |
N36702A |
100 m / 328.1 ft |
| 00LT922 |
N36702A |
150 m / 492.1 ft |
Table 4. OM5 LC to LC multimode Jumpers
| Fixed length part number |
EC |
Length |
| 01PP370 |
N36754 |
1 m / 3.3 ft |
| 01PP371 |
N36754 |
2 m / 6.6 ft |
| 01PP372 |
N36754 |
3 m / 9.8 ft |
| 01PP373 |
N36754 |
5 m / 16.4 ft |
| 01PP374 |
N36754 |
8 m / 26.2 ft |
| 01PP375 |
N36754 |
10 m / 32.8 ft |
| 01PP376 |
N36754 |
13 m / 42.7 ft |
| 01PP377 |
N36754 |
15 m / 49.2 ft |
| 01PP378 |
N36754 |
20 m / 65.6 ft |
| 01PP379 |
N36754 |
40 m / 131.2 ft |
| 01PP380 |
N36754 |
80 m / 262.5 ft |
| 01PP381 |
N36754 |
120 m / 423.2 ft |
| 01PP382 |
N36754 |
150 m / 492.1 ft |
| 01PP383 |
N36754 |
Custom |
Table 5. Available lengths
| All FICON®/FCP, Coupling Links, OSA, and multimode jumpers |
Single Mode jumpers |
PSIB |
| 7 m (20 ft) |
4 m (12 ft) |
|
| 13 m (40 ft) |
13 m (40 ft) |
|
| 22 m (70 ft) |
22 m (70 ft) |
|
| 31 m (100 ft) |
31 m (100 ft) |
|
| 46 m (150 ft) |
61 m (200 ft) |
|
| 61 m (200 ft) |
92 m (300 ft) |
150m (492 ft) |
| custom |
122 m (400 ft) |
|
Notes:
- Before ordering, consider length requirements for future equipment
relocation.
- The maximum total jumper cable length cannot exceed 244 meters
(800 ft) when using either 50/125 μm trunk fiber or when a 62.5/125 μm
link exceeds 2 kilometers (1.24 miles).
- English distances are approximate.
- Custom lengths are available in 0.5 meter increments from 4 meters
(12 ft) to 500 meters (1640 ft).
|