GPFS error messages for unsuccessful GPFS commands
This topic describes the error messages for unsuccessful GPFS commands.
If message 6027-538 is returned from the mmcrfs command,
verify that the disk descriptors are specified correctly and that
all named disks exist and are online. Issue the mmlsnsd command
to check the disks.
- 6027-538
- Error accessing disks.
If the daemon failed while
running the command, you can see message 6027-663. Follow the procedures in GPFS daemon went down.
- 6027-663
- Lost connection to file system daemon.
If the daemon was not running
when you issued the command, you can see message 6027-665. Follow the procedures in GPFS daemon does not come up.
- 6027-665
- Failed to connect to file system daemon: errorString.
When GPFS commands
are unsuccessful, the system may display information similar to these
error messages:
- 6027-1627
- The following nodes are not aware of the configuration server change: nodeList. Do not start GPFS on the preceding nodes until the problem is resolved.