GPFS error messages for unsuccessful GPFS commands

This topic describes the error messages for unsuccessful GPFS commands.

If message 6027-538 is returned from the mmcrfs command, verify that the disk descriptors are specified correctly and that all named disks exist and are online. Issue the mmlsnsd command to check the disks.
6027-538
Error accessing disks.
If the daemon failed while running the command, you can see message 6027-663. Follow the procedures in GPFS daemon went down.
6027-663
Lost connection to file system daemon.
If the daemon was not running when you issued the command, you can see message 6027-665. Follow the procedures in GPFS daemon does not come up.
6027-665
Failed to connect to file system daemon: errorString.
When GPFS commands are unsuccessful, the system may display information similar to these error messages:
6027-1627
The following nodes are not aware of the configuration server change: nodeList. Do not start GPFS on the preceding nodes until the problem is resolved.