Capacity information is not available in GUI pages
The IBM Storage Scale management GUI does not display the capacity information on various GUI pages if GPFSDiskCap and GPFSFilesetQuota sensors are disabled and quota is disabled on the file system.
The following table provides the solution for the capacity data display issues in the corresponding GUI pages.
| GUI page | Solution |
|---|---|
| Verify whether the GPFSPool sensor is enabled on at least one node and ensure that the file system is mounted on this node. The health subsystem might have enabled this sensor already. The default period for the GPFSPool sensor is 300 seconds (5 minutes). | |
| does not display fileset capacity details. | In this case, the quota is not enabled for the file system that hosts this fileset. Go to page and enable quotas for the corresponding file system. By default, the quotas are disabled for all file systems. |
| Verify whether the GPFSDiskCap and GPFSFilesetQuota sensors are enabled and quota is enabled for the file systems. For more information on how to enable performance monitoring sensors, see Configuring performance monitoring options in GUI. |