GDS events

The following table lists the events that are created for the GDS component.

Table 1. Events for the GDS component
Event Event
Type
Severity Call Home Details
gds_check_bad STATE_CHANGE ERROR no Message: The GDS check has failed.
Description: The GDS test program gdscheck did not return the expected success message.
Cause: The GDS check has failed.
User Action: Check the GDS configuration and settings for the gdscheckfile parameter. For more information, see the 'gpudirect' section of the '/var/mmfs/mmsysmon/mmsysmonitor.conf' system health monitor configuration file.
gds_check_ok STATE_CHANGE INFO no Message: The GDS check is OK.
Description: The GDS test program gdscheck returned successfully.
Cause: N/A
User Action: N/A
gds_check_warn INFO WARNING no Message: The GDS state cannot be determined.
Description: The GDS test program has failed or ran into a timeout.
Cause: The GDS test program failed or ran into a timeout.
User Action: Check the GDS configuration and settings for the gdscheckfile parameter. For more information, see the 'gpudirect' section of the '/var/mmfs/mmsysmon/mmsysmonitor.conf' file.
gds_prerequisite_bad STATE_CHANGE ERROR no Message: The GDS prerequisite check for enabled RDMA failed.
Description: The verbsRdma, which is an RDMA prerequisite, is not enabled in the IBM Storage Scale configuration.
Cause: The GDS fails when the RDMA is disabled.
User Action: Check the RDMA configuration and enable verbsRdma by using the mmchconfig command.