GDS events
The following table lists the events that are created for the GDS component.
Event | Event Type |
Severity | Call Home | Details |
---|---|---|---|---|
gds_check_bad | STATE_CHANGE | ERROR | no | Message: The GDS check has failed. |
Description: The GDS test program gdscheck did not return the expected success message. | ||||
Cause: The GDS check has failed. | ||||
User Action: Check the GDS configuration and settings for the gdscheckfile parameter. For more information, see the 'gpudirect' section of the '/var/mmfs/mmsysmon/mmsysmonitor.conf' system health monitor configuration file. | ||||
gds_check_ok | STATE_CHANGE | INFO | no | Message: The GDS check is OK. |
Description: The GDS test program gdscheck returned successfully. | ||||
Cause: N/A | ||||
User Action: N/A | ||||
gds_check_warn | INFO | WARNING | no | Message: The GDS state cannot be determined. |
Description: The GDS test program has failed or ran into a timeout. | ||||
Cause: The GDS test program failed or ran into a timeout. | ||||
User Action: Check the GDS configuration and settings for the gdscheckfile parameter. For more information, see the 'gpudirect' section of the '/var/mmfs/mmsysmon/mmsysmonitor.conf' file. | ||||
gds_prerequisite_bad | STATE_CHANGE | ERROR | no | Message: The GDS prerequisite check for enabled RDMA failed. |
Description: The verbsRdma, which is an RDMA prerequisite, is not enabled in the IBM Storage Scale configuration. | ||||
Cause: The GDS fails when the RDMA is disabled. | ||||
User Action: Check the RDMA configuration and enable verbsRdma by using the mmchconfig command. |