Unable to generate the accurate container listing by performing a GET operation for unified file and object access container
Refer to the following information for troubleshooting references and steps for resolving system errors when your system is unable to generate the accurate container listing. Use the GET operation for unified file and object access containers.
Description
The accurate container listing for a unified file or an object access-enabled container is not displayed on the system.
Cause
This error occurs under one or both of the following conditions:
- A longer time is taken to update and display the listing because the ibmobjectizer interval is too long.
- Objectization phis not supported for the files that you create on the file system.
Proposed workaround
Tune the ibmobjectizer interval configuration by running the following command to set up the
objectization
interval:
mmobj config change --ccrfile spectrum-scale-objectizer.conf \
--section DEFAULT --property objectization_interval --value 2400
This command sets an interval of 40 minutes between the completion of an objectization cycle and the start of the next cycle.