Firewall recommendations for Performance Monitoring tool

The IBM Storage Scale system uses the following ports for the Performance Monitoring tool to work.

Table 1. Recommended port numbers that can be used for Performance Monitoring tool
Port Number Protocol Service Name Components that are involved in communication
4739 TCP and UDP Performance Monitoring tool Intra-cluster. This port needs to be accessible by all sensor nodes that are sending performance monitoring data.
8123 TCP Object Metric collection Intra-cluster
8124 TCP Object Metric collection Intra-cluster
8125 UDP Object Metric collection Intra-cluster
8126 TCP Object Metric collection Intra-cluster
8127 TCP Object Metric collection Intra-cluster
9085 TCP Performance Monitoring Tool Intra-cluster. This port needs to be open to all nodes where the performance collector is running. This port is used for internal communication between the collectors.
9980 TCP Performance Monitoring Tool Intra-cluster
Important:
  • The 4739 port needs to be open when a collector is installed.
  • The 9085 port needs to be open when there are two or more collectors.
  • If the port 9980 is closed, accessing the collector remotely, or connecting external tools or even connecting another instance of the GUI remotely, is not possible.