essutils - SSR Tools menu

ESS Installation and Deployment Toolkit (essutils) SSR Tools menu

Synopsis

CHECK SYSTEM HARDWARE AND SOFTWARE
1.  Help
2.  ESS Legacy (p8)	
3.  ESS 3000 SSR checks
4.  ESS 5000 SSR checks
5.  ESS 3200 SSR checks
6.  ESS 3500 SSR checks
7.  ESS 6000 SSR checks
8.  p8 EMS checks
9.  p9 EMS or p9 Protocol checks
10. Utility Node SSR Checks
11. Back  

SSR Checks for Legacy p8 nodes


1. SSR Checks for Legacy p8 nodes1.  Quick storage configuration check    
2.  Check enclosure cabling and paths to disks 
3.  Check disks for IO operations              
4.  Check for servicable event                 
5.  Gather servicable event ID details         
6.  Erase servicable event ID                  
7.  Set FSP ipmi IP address (HMC1 port)        
8.  Set FSP ipmi static state and netmask (HMC1 port)          
9.  Check FSP interface (HMC1 port)            
10. Assign IP address to Management Interface (P8 C10-T1|C12-T1)) 
11. Check management interface (POWER 8 C10-T1|C12-T1)
12. Ping tests
13. Check IPR Array status
14. Back

SSR Checks for ESS 3000 nodes

1. Quick storage configuration check    
2. Check enclosure cabling and paths to disks  
3. Check disks for IO operations               
4. Check the memory (ESS 3000)                 
5. Check the CPU (ESS 3000)                    
6. Assign IP address to Interface (Port 1 ESS 3000)   
7. Check management interface (ESS 3000 Port 1)
8. Ping tests                                  
9. Back

SSR Checks for ESS 5000 nodes

1.  Quick storage configuration check
2.  Check enclosure cabling and paths to disks 
3.  Check disks for IO operations              
4.  Check for servicable event                 
5.  Gather servicable event ID details         
6.  Erase servicable event ID                  
7.  Set FSP ipmi IP address (HMC1 port)        
8.  Set FSP ipmi static state and netmask (HMC1 port) 
9.  Check FSP interface (HMC1 port)            
10. Set FSP ipmi IP address (HMC2 port)        
11. Set HMC2 default gateway                   
12. Set FSP ipmi static state and netmask (HMC2 port) 
13. Check FSP interface (HMC2 port)            
14. Assign IP address to Management Interface (C11-T1)
15. Check management interface (C11-T1)        
16. Ping tests                                 
17. WCE test                                   
18. Check IPR Array status                     
19. Back

SSR Checks for ESS 3200 nodes

1.  Quick storage configuration check   
2.  Check enclosure cabling and paths to disks       
3.  Check disks for IO operations       
4.  Set FSP ipmi IP address (ESS 3200) (HMC1|BMC)    
5.  Set FSP ipmi static state and netmask (ESS 3200) (HMC1|BMC)   
6.  Check FSP interface (ESS 3200) (HMC1|BMC)        
7.  Assign IP address to Management Interface (ESS 3200)            
8.  Check management interface (3200)   
9.  Set BMC VLAN tag                    
10. Confirm BMC VLAN tag                
11. Ping tests                          
12. Run passwordless ssh check          
13. Fix passwordless ssh                
14. Check the memory (ESS 3200)         
15. Check the CPU (ESS 3200)            
16. Check for any incorreclty formatted drives       
17. Check Product Manufacturer          
18. Check Product Name                  
19. Check for any bad sensors           
20. Back  

SSR Checks for Storage Scale System 3500 nodes

1. Installation and Deployment Toolkit
2. Service Toolkit
3. Back

SSR Checks for Storage Scale System 6000 nodes

1. Installation and Deployment Toolkit       
2. Service Toolkit
3. Back

SSR Checks for p8 EMS

1. Assign IP address to FSP Interface (EMS P8 C10-T4)              
 2. Check FSP interface (POWER 8 EMS C10-T4)                        
 3. Assign IP address to Management Interface (P8 C10-T1|C12-T1))   
 4. Assign IP address to Campus Interface (EMS P8 C10-T3)           
 5. Check management interface (POWER 8 C10-T1|C12-T1)              
 6. Check campus interface (POWER 8 C10-T3)                         
 7. Check for servicable events (EMS ONLY)                          
 8. Gather servicable event ID details (EMS ONLY)                   
 9. Erase servicable event ID (EMS ONLY)                            
10. Set FSP ipmi IP address (HMC1 port)                             
11. Set FSP ipmi static state and netmask (HMC1 port)               
12. Check FSP interface (HMC1 port)                                 
13. Quick storage configuration check                               
14. Ping tests                                                      
15. Check IPR Array status                                          
16. Back 

SSR Checks for p9 EMS or p9 Protocol

1.  Assign IP address to Management Interface (EMS P9 C11-T1)     
2.  Assign IP address to Management Interface (Protocol P9 C11-T1)
3.  Assign IP address to FSP Interface (EMS P9 C11-T2)            
4.  Check management interface (EMS POWER 9 C11-T1)               
5.  Check management interface (Protocol POWER 9 C11-T1)          
6.  Check FSP interface (POWER 9 EMS C11-T2)                      
7.  Assign IP address to Campus Interface (EMS P9 C11-T3)         
8.  Check Campus interface (POWER 9 EMS C11-T3)                   
9.  Check for servicable events (EMS ONLY)                        
10. Gather servicable event ID details (EMS ONLY)                 
11. Erase servicable event ID (EMS ONLY)                          
12. Set FSP ipmi IP address (HMC1 port)                           
13. Set FSP ipmi static state and netmask (HMC1 port)             
14. Check FSP interface (HMC1 port)                               
15. Set FSP ipmi IP address (HMC2 port)                           
16. Set HMC2 default gateway                                      
17. Set FSP ipmi static state and netmask (HMC2 port)             
18. Check FSP interface (HMC2 port)                               
19. Quick storage configuration check                             
20. Ping tests                                                    
21. Check IPR Array status                                        
22. Back 

SSR Checks for Storage Scale System Utility Node

1. Installation and Deployment Toolkit       
2. Service Toolkit
3. Back

Availability

Available with IBM Storage Scale System.

Description

The SSR Tools menu allows users to check ESS for proper hardware installation, system configuration, and SAS connectivity. Using this menu item, users can perform the basic validation of the system once it arrives from manufacturing.

Menu options

1. Help
Opens this manual page.
2. Check and validate various install parameters
Performs check of various installation parameters. Address items identified as WARN or ERROR. Some parameters can not be checked until the system is fully deployed. For more information, see essinstallcheck command.
essinstallcheck -N ems1,ess_x86_64

Press c to change the EMS host name and I/O server nodes group name or I/O server node host name.

3. Quick storage configuration check
Performs a brief check of installed adapters and connected disks in the system. For more information, see essstoragequickcheck command.
essstoragequickcheck -N localhost

Press c to change the EMS host name and I/O server nodes group name or I/O server node host name.

4. Check enclosure cabling and paths to disks
Performs storage cable connection and topology check. This test is meaningful when run on I/O server nodes. For more information, see essfindmissingdisks command.
essfindmissingdisks -N localhost

Press c to change the EMS host name and I/O server nodes group name or I/O server node host name.

5. Check disks for IO operations
Performs I/O operations to the attached disks. This test should only be run in a test environment. The node name must match the host name of the node. For more information, see esscheckdisks command.
ESSENV=INSTALL esscheckdisks --enclosure-list all --iotest a --write-enable --local

Press c to change the EMS host name and I/O server nodes group name or I/O server node host name.

6. Check the memory configuration
Checks for a valid memory configuration within the canister.
ess3kplt -t memory
7. Check the CPU configuration
Checks for a valid CPU configuration within the canister.
ess3kplt -t cpu
8. Assign IP address to Interface
Assigns IP address to the provided interface.
essgennetworks -N localhost --interface enP3p9s0f0 --assignip 198.51.100.20 --netmask /24
   

Press c to customize the command options. Change IP address as needed.

9. Ping tests
Pings all nodes in the node list. For more information, see essruntask command.
essruntask -N 198.51.100.10 --task ping --mode ota

Press c to change the EMS host name and I/O server nodes group name or I/O server node host name.

10. Back
Exit to the previous menu.

Exit status

0
Successful completion.
nonzero
A failure has occurred.

Security