Hardware configuration planning
This topic describes the hardware configuration to be used for FPO model and IBM Storage Scale client node in shared storage model.
Configuration | Recommended configuration |
---|---|
Network | At least one 10Gb+ ethernet adapter or IB adapters |
Disk | SAS disks, 8~12 disks per node |
Memory | 100+ GB per node |
CPU | 8+ logic processors |
Note: For X86_64, with hyper thread on (by default), one physical core is mapped to two logic
processors. For ppc64le, SMT 4 is recommended and one physical core is mapped to four logic
processors.
Configuration | Recommended configuration |
---|---|
Network | At least one 10 Gb+ ethernet adapter or IB adapters |
Disk | SAS disks, ~ 6 disks for shuffle if possible |
Memory | 100+ GB per node |
CPU | 8+ logic processors |
Note: It is better to take the same hardware configurations for all Hadoop nodes.