You can use the tsmdlst command to display the device names needed to
define paths between the SAN devices, the storage agent, and the IBM Storage Protect
server.
Before you begin
If you did not add the storage agent path to the search path, you must first change to the
directory where the storage agent program is located. By default, the path is c:\program
files\tivoli\tsm\StorageAgent.
Procedure
Obtain tape-device information by completing the following steps:
-
Ensure that the device driver is running. If the device driver is not running, the command
gives results that might be incorrect.
-
Enter tsmdlst at an MS-DOS command prompt. If you do not specify any
parameters, a summary of device information for the local computer is displayed.
Results are displayed in the following format:
Computer Name: ATLAS
TSM Device Driver: TSMScsi - Running
2 HBAs were detected.
Manufacturer Model Driver Version Firmware Description
---------------------------------------------------------------------------------------
QLogic Corp QLA2462 ql2300.sys 9.1.9.25 5.04.02 QLogic QLA2462 Fibre Channel Adapter
QLogic Corp QLA2462 ql2300.sys 9.1.9.25 5.04.02 QLogic QLA2462 Fibre Channel Adapter
TSM Name ID LUN Bus Port SSN WWN TSM Type Driver Device Identifier
----------------------------------------------------------------------------------------
mt0.0.0.3 0 0 0 3 HU1206LY0B ..638D LTO NATIVE HP Ultrium 5-SCSI Y50S
mt1.0.0.3 1 0 0 3 HU1206LY9N ..6390 LTO NATIVE HP Ultrium 5-SCSI Y5AS
mt2.4.0.3 2 4 0 3 8395261003 ..C358 LTO IBM IBM ULT3580-TD3 5AT0
lb3.0.0.3 3 0 0 3 1333508999 ..7A14 LIBRARY TSM ATL P3000 0100
mt3.1.0.3 3 1 0 3 1333508000 ..7A14 DLT TSM QUANTUM DLT7000 0100
To issue the DEFINE PATH and UPDATE PATH commands on the
server, you need the names in the column labeled TSM Name.