To optimize disk storage, review the guidelines for setting up disk storage with IBM® Storage Protect. Then, provide a connection between the server and the disk storage devices and complete other configuration tasks.
Procedure
-
Provide a connection between the server and the storage devices by following these
guidelines:
- Use a switch or direct connection for Fibre Channel connections.
- Consider the number of ports that are connected and account for the amount of bandwidth that is
needed.
- Consider the number of ports on the server and the number of host ports on the disk system that
are connected.
-
Verify that device drivers and firmware for the server system, adapters, and operating
system are current and at the recommended levels.
-
Configure storage arrays. Make sure that you planned properly to ensure optimal
performance.
-
Ensure that the server system has access to disk volumes that are created. Complete the
following steps:
-
If the system is connected to a Fibre Channel switch, zone the server to see the disks.
-
Map all of the volumes to tell the disk system that this specific server is allowed to see each
disk.
-
Ensure that tape and disk devices use different Host Bus Adapter (HBA) ports. Control tape and
disk I/O by using the SAN. Use separate Fibre Channel ports for tape and disk I/O.